RES2404-PTP-PoE User Guide. Rev. 1.0
www.kontron.com
// 26
4/
Installation
This section gives instructions for accessing the Command Line Interface (CLI) of the RES2404-PTP-PoE using either
in-band access via the Ethernet fabric or the out-of-band management interfaces like serial port or Gigabit Ethernet
accessible from the front plate connector. The CLI is required for configuring the switch. Furthermore this chapter
delivers information and procedures for commissioning of the unit. This includes the following:
Safety requirements
Cooling
Mounting
Software Installation
4.1.
Safety Requirements
The RES240-PTP-PoE is designed for easy installation. However, the following safety precautions must be observed
when installing or operating the RES2404-PTP-PoE. Kontron assumes no responsibility for any damage resulting
from failure to comply with these requirements.
Warning!
The power connector is the product’s main disconnect device and must be easily
accessible.
Electric Shock Hazard!
The RES2404-PTP-PoE require AC mains power in the range from 110 to 240 volts for
operation. Therefore, due caution must be exercised in handling or performing operations
when power is applied. Failure comply with the above could endanger your life or health.
ESD Equipment!
The RES2404-PTP-PoE contains electrostatically sensitive devices. Please observe the
necessary precautions to avoid damage to your system:
Discharge your clothing before touching the assembly. Tools must be discharged
before use.
Do not touch any system components, connector pins, or system conductive
circuits.
If working at an anti-static workbench with professional discharging equipment,
ensure compliance with its usage when handling this product.
4.2.
Cooling
The RES2404-PTP-PoE includes forced-air cooling which is provided by four fans at the back side of the system. Air
inlets are located at the front side. Adequate ambient airflow to the fan inlet areas must be ensured and the area
behind the system must also provide for adequate outlet airflow. Direct re-cycling of outlet air to the inlet area must
be avoided to preclude overheating of the system.
If the RES2404-PTP-PoE is operated at temperatures above 45°C, ensure that an inlet area
and an outlet area of 1U (44.45 mm) are provided. Failure to comply with the above may
cause improper operation of or damage.