SmartClient-KLU - User Guide, Rev. 1.2
// 29
6.2.
DC Power Connection
The SmartClient-KLU is connected to a DC power source via a DC power supply wiring (only the Phoenix power plug
terminal is included).
The SmartClient-KLU is delivered with a DC power plug terminal (2-pin Phoenix connector). For DC connection,
prepare the connecting wires using the supplied Phoenix plug terminal.
Figure 12: Phoenix power plug terminal
1
Slotted pan head screw for securing the wire
2
Slotted pan head screw for securing the Phoenix plug terminal to the Phoenix connector
3
Location for inserting the positive (+) input wire
4 Location for inserting the negative (-) input wire
6.2.1.
Cabling
For the pin assignment Phoenix power plug terminal refer to the subsection 10.1.1 "Power Input Connector".
1.
Cut the required length two isolated wires ( 1mm2) AWG 18 and strip each end 5 ~ 7 mm.
2.
Twist the striped wire-ends and provide them with ferrules.
3.
Loosen the two slotted pan head screws of the DC plug terminal far enough so that you can insert the end of the
prepared wires.
4.
Insert the wires into the corresponding clamp of the Phoenix plug terminal. Make sure that you have the right
polarity of the connection [refer to Figure 12 or subsection 10.1.1 "Power Input Connector"].
5.
Fasten the screws to secure the wires into the clamps of the plug terminal.