14
KON SOBEK Drives GmbH · Etzwiesenstraße 35/1 · D- 72108 Rottenburg am Neckar
Tel: +49 (0) 7457/9435-0 · Hotline: 0800-Brushless · Fax: +49 (0) 7457/9435-90 ·
E-Mail: info@kontronik.com
Warnings:
The limits for the warnings communicated by a TelME
module can be set here.
o
Battery cut off
- TelMe-Parameter.
Threshold for Battery cut off / cell. Here the
warning on the transmitter is activated.
Limits
: Min 700mV - Max 4400mV
Default
: 3500mV
o
Capacity limit
-TelMe-Parameter.
Threshold for Capacity limit in Ah. Here the
warning on the transmitter is activated.
Limits
: Min 0.0Ah - Max 65.0Ah
Default
: 0.0 means not active
o
Max. motor current
- TelMe-Parameter.
Threshold for motor current peaks in A. Here the
warning on the transmitter is activated.
o
Max. BEC current
- TelMe-Parameter.
Threshold for BEC current in mA. Here the
warning on the transmitter is activated. (Only with
ESCs having BEC current measuring. Not for all
transmitters)
Limits
: Min 0mA - Max 30000mA
o
Max. Fet temperature
- TelMe-Parameter
Threshold for temperature of power MosFets in
°C, Here the warning on the transmitter is
activated.
Limits
: Min 20°C - Max 90°C
Default
: 90°C
o
Max. BEC temperature
- TelMe-Parameter
Threshold for BEC temperature in °C Here the
warning on the transmitter is activated. (Only at
ESCs with BEC)
Limits
: Min 20°C - Max 90°C
Default
: 90°C
Expert:
o
Min. PWM
– The minimum possible PWM
value. Influences the start up behavior.
Limits
: Min 1% - Max 25%
o
Max. starting current
– Limitation of current
during start up in A. Influences start up
behavior.
Limits
: Min 10A - Max 100A
o
Slewrate Pos.
– Acceleration rate of the
motor. Time refers to 0-100% PWM!
Limits
: Min 100ms - Max 60000ms
Default
: 1000ms
o
Slewrate Neg
. - Deceleration rate of the
motor. Time refers to 0-100% PWM!
Limits
: Min 100ms - Max 60000ms
Default
: 1000ms
o
Brake-Slewrate Pos.
– Acceleration rate of full
brake strength. Time refers to 0-100% brake
strength!
Limits
: Min 100ms - Max 10000ms
Default
: 1000ms
o
Brake-Slewrate Neg
. - Deceleration rate of full
brake strength. Time refers to 0-100% brake
strength!
Limits
: Min 100ms - Max 10000ms
Default
: 1000ms
o
Min. PWM brake.
– Possible weakness of
brake compared to maximum brake strength.
Only if proportional brake is active.
Limits
: Min 0% - Max 50%
Default
: 0%
o
Max. PWM brake.
– Possible strength of brake
compared to maximum brake strength. Only if
proportional brake is active.
Limits
: Min 50% - Max 100%
Default
: 100%