Page 1: ...KCM series 4K LCD Monitors USER MANUAL V1 3 Shenzhen Konvision Technology Co Ltd http www konvision com ...

Page 2: ...td www konvision com 2 About This Manual The instructions in this manual are for KCM Series 4K LCD monitors The following description use model KCM 2460W pictures Please confirm the model number of the device before reading this manual ...

Page 3: ...u 16 Menu Operation 16 Menu Item Description 16 1 Main menu 17 2 Sub Menu 17 Status Display 17 Function Settings 18 Marker Settings 20 Waveform 23 Aux settings 25 Color Settings 26 Video Settings 28 Source Settings 30 Audio Settings 31 CC Settings 33 IMD Settings 35 OSD Settlings 37 Key Lock 38 Factory Settings 38 Remote Control 39 AC Power Connection 40 ...

Page 4: ...inal is good in order to avoid electric shock 7 Please do not open the back cover to avoid electric shock Please contact professionals for service need 8 If there is no image or sound please unplug the power cord from the AC outlet immediately Please consult professionals if there still have problems after examining carefully 9 Do not place this product at unstable places such as cars shelves or t...

Page 5: ...ly wiping with lint free cloth to remove dust For the more difficult cleaning use lint free cloth that has been very lightly dampened with detergent then dry any excess moisture from the monitor or LCD panel immediately to prevent damage Cabinet Maintenance Please follow the guidelines below to prevent potential damage Do not wipe the cabinet with solvents such as alcohol thinner or gasoline Do no...

Page 6: ...wing situations occur please turn off the power do not insert the plug and contact a professional service staff to deal with timely A This product smells smoke and off flavor B When this product displays abnormal operating conditions such as there is no picture or sound C When any liquid is splashed into the product or product dropped D When the product soaked or fall into the water E When the pro...

Page 7: ...tem PAL NTSC SECAM This unit detects the color system automatically 3D Video Decoder Process 3D decoding on VIDEO signals to realize better reduce cross color Motion Adaptive Interlace to Progressive It converts interlaced video to progressive video by motion detection reduce the serrated image 10BIT signal processing Signal input signal processing and image output are 10bit data processing to ens...

Page 8: ...f the input signal Audio level meter UV PPM Show the audio level meter UV PPM for SDI embedded audio Waveform Display input signal waveform and color scope for SDI signal input monitoring It includes luminance waveform CbCr waveform Luminance waveform will mark with red if over the value specified by user Focus Assist Focus assist is to aid the cameraman focus on the main body by marking the sharp...

Page 9: ... U and V components respectively and the vector calibration circle indicates the phase hue of the chrominance signal Time Code Display Time code display is to display SMPTE time code LTC VITC1 or VITC2 under SDI input for identifying and synchronizing video data streams Remote Control Available to connect to the remote terminal to operate the equipment directly select the input signal longitudinal...

Page 10: ...rol the Menu Please contact the dealer for Konvision Device Controller software 2 Power Button and Indicator When the external AC power supply with electricity the indicator light is red Press this POWER button to power on the monitor and the indicator light turns blue Press this button for more than 2 seconds to turn off the monitor indicate light turns to red 3 SDI Button and Indicator Press thi...

Page 11: ... Mode Single HDMI input signal full screen display mode HDMI Quad View Mode 4 channel HDMI input signal consisting of 4 screen display mode 4 channel HDMI can enter different resolution signals 6 WINSEL Button Under the single signal window press the WINSEL key to switch the input signal path When the SDI signal is in the SDI Single Mode display mode press the WINSEL key in succession to switch th...

Page 12: ...ould be turned to left direction 11 UP Button While in the menu press this key to select the up operation Note If operation panel is with IMAGE ADJ knob IMAGE ADJ knob should be turned to right direction 12 ENTER Button Press to select the OK operation While the menu is operating press the ENTER key to enter the next menu or to confirm the selected parameter When not in the menu pressing ENTER con...

Page 13: ...Shenzhen Konvision Technology Co Ltd www konvision com 13 B Rear View 1 DC 12V IN 12V DC power supply ...

Page 14: ...can be set in the menu function option 2 GPI2 when connect GND GPI2 works GPI2 function can be set in the menu function option 3 GPI3 when connect GND GPI3 works GPI3 function can be set in the menu function option 4 NC Not connect 5 NC Not connect 6 GPI4 when connect GND GPI4 works GPI4 function can be set in the menu function option 7 NC Not connect 8 GND Ground 4 LAN Ethernet port for remote ne...

Page 15: ... NC 8 NC NC 6 SDI1 SDI2 SDI3 SDI4 Input Loop out Used for SDI signal input and output In the SDI Square Mode display mode display 4K signal consist of SDI1 SDI2 SDI3 SDI4 inputs simultaneously In the SDI 2 SI Mode display mode display 4K signal consist of SDI1 SDI2 SDI3 SDI4 inputs simultaneously In the SDI Quad View Mode mode SDI1 SDI2 SDI3 SDI4 access different resolution signals while displayin...

Page 16: ...ut used for monitoring with 3 5mm earphone 9 Speaker Speaker output OSD Menu Menu Operation Press MENU to enter the main menu then press UP or DOWN to switch between options in the same menu After you find the corresponding option press ENTER to enter the next menu and then press UP or DOWN to find the corresponding Parameter press ENTER key first then press UP key or DOWN key to adjust the value ...

Page 17: ... contains the following items Main menu options Sub menu Status Display 1 Function Settings 1 Marker Settings 1 Waveform 1 Aux Settings 1 Color Settings 1 Video Settings 1 Input Settings 1 Audio Settings 1 CC Settings 1 IMD Setting 1 Menu Setting 1 Key Lock 1 2 Sub Menu Status Display ...

Page 18: ...ness Display current image brightness Contrast Display current image contrast Scan Mode Display current scan mode Color Temp Display color temp Frame Ratio Display drawing ratio HDR Display selected HDR mode IP Address Display factory default IP address 192 168 1 155 DSP Version Display machine internal DSP software version information CPU Version Display machine internal CPU software version info...

Page 19: ...F1 Undefined W Form Mode Vector Scope Histogram Audio Meter Focus Assistant False Color Zebra Blue Mono Red Green Time Code The function keys can be set to the following functions W Form Mode Vector Scope Histogram Audio Meter Focus Assistant False Color Zebra Blue Mono Red Green Time Code Static Frame Mute Markup Control ...

Page 20: ...above GPI1 Undefined Markup Control Red Tally Green Tally Blue Mono SDI HDMI Layout The function keys can be set to the following functions Markup Control Red Tally Green Tally Blue Mono SDI HDMI Layout GPI2 Same as above Same as above GPI3 Same as above Same as above GPI4 Same as above Same as above Marker Settings ...

Page 21: ...ll markers Turn off all markers Area Marker OFF 4 3 15 9 14 9 13 9 1 85 1 2 35 1 No Area Marker Area Marker ratio 4 3 Area Marker ratio 15 9 Area Marker ratio 14 9 Area Marker ratio 13 9 Area Marker ratio 1 85 1 Area Marker ratio 2 35 1 Center Marker OFF ON Turn off Center Marker Turn on Center Marker Safety Area OFF 80 No Safety Area 80 Safety Area ...

Page 22: ...it Marker OFF ON Turn off Fit Marker Turn on Fit Marker Marker Mat OFF Black Translucency Gray Turn off Marker Mat Turn on Marker Mat as Black Turn on Marker Mat as Translucency Turn on Marker Mat as Gray Marker Line OFF White Green Gray Turn off Turn on Marker Line as White Turn on Marker Line as Green Turn on Marker Line as Gray ...

Page 23: ... Display YCbCr waveform Display RGB waveform Waveform Scale Digital IRE Waveform scale is displayed numerically Waveform scale is displayed as a percentage of brightness Waveform Alarm 80 100 The waveform alarm display can be set to any percentage within the range of 80 100 When the measured waveform reaches or exceeds this percentage an alarm will occur and the alarm will be indicated in red ...

Page 24: ...togram Display brightness histogram Display RGB histogram Channel Select Channel 1 Channel 2 Channel 3 Channel 4 4K Mode Select to display channel 1 waveform separately Select to display channel 2 waveform separately Select to display channel 3 waveform separately Select to display channel 4 waveform separately 4K picture measurement waveform composed of 4 input channels in 4K mode ...

Page 25: ... on False Color Turn off False Color Focus Assist ON OFF Turn on Focus Assist Turn off Focus Assist Focus Gain 0 31 Focus Gain 0 31 Zebra ON OFF Turn on Zebra Turn off Zebra Zebra Level 80 100 The zebra line scale can be set to any percentage within the range of 80 100 When the brightness in the picture reaches or exceeds this percentage an alarm will ...

Page 26: ...rn off H Flip Time Code ON OFF Turn on Time Code Turn off Time Code Color Settings Color Setting Sub Menu Settings Setting Option Description Data Levels Limited Range 64 940 Extended Range 64 1023 Full Range 0 1023 Custom Select Limited Range Mode Select Extended Range Mode Select Full Range Mode Select Custom Mode Color Temp 5500K Select Color Temp 5500K ...

Page 27: ...as 0 255 Color Table Bypass Rec709 EBU SMPTE C DCI P3 Rec2020 USER 1 USER 2 Color Table Select Bypass Color Table Select REC709 Color Table Select EBU Color Table Select SMPTE C Color Table Select DCI P3 Color Table Select Rec2020 Color Table Select USER1 Color Table Select USER2 Gamma OFF Gamma 2 0 Gamma 2 2 Gamma 2 4 Gamma 2 6 Rec 2100 HLG 1 0 Rec 2100 HLG 1 1 Rec 2100 HLG 1 2 Rec 2100 HLG 1 3 R...

Page 28: ...hnology Co Ltd www konvision com 28 ST2084 300nit ST2084 500nit ST2084 800nit ST2084 1000nit S Log3 User HDR OFF Rec 2100 HLG ST2084 HDR10 Ture off HDR HDR select Rec 2100 HLG mode HDR selectST2084 HDR10 mode Video Settings ...

Page 29: ...nal Ratio 1 1 The screen is displayed in Full Screen The screen is displayed in the original scale of the input signal The screen is displayed as 1 1 Freeze OFF ON Turn off Freeze Turn on Freeze Scan Mode OFF ON Turn off Scan mode Turn on Scan mode Blue Mode OFF Mono Blue Red Turn off the color display mode Black and white mode display image ...

Page 30: ... green mode display image Source Settings Source Settings Sub Menu Settings Setting Option Description Window Select Window 1 Window 2 Window 3 Window 4 Select window 1 Select window 2 Select window 3 Select window 4 Source Select SDI1 SDI2 SDI3 SDI4 Source Select SDI1 Source Select SDI2 Source Select SDI3 Source Select SDI4 ...

Page 31: ...ect HDMI3 Source Select HDMI4 Audio Settings Audio Settings Sub Menu Settings Setting Option Description Audio Source Undefined SDI1 SDI2 SDI3 SDI4 HDMI1 HDMI2 Audio Source Undefined Audio Source select SDI1 Audio Source select SDI2 Audio Source select SDI3 Audio Source select SDI4 Audio Source select HDMI1 Audio Source select HDMI2 ...

Page 32: ...l Select audio output CH9 CH10 Channel Select audio output CH11 CH12 Channel Select audio output CH13 CH14 Channel Select audio output CH15 CH16 Channel Audio Meter OFF ON Turn off Audio Meter Turn on Audio Meter Meter Direction Vertical Horizontal Audio meter vertical display Audio meter horizontal display Meter Select CH1 2 CH1 4 CH5 6 CH5 8 CH5 10 CH9 12 CH13 14 Select meter channel CH1 2 Selec...

Page 33: ...lect meter channel CH13 16 CC Settings CC Setting Sub Menu Settings Setting Option Description Channel Select Channel 1 Channel 2 Channel 3 Channel 4 4K Mode Select single channel SDI1 CC Select single channel SDI2 CC Select single channel SDI3 CC Select single channel SDI4 CC ...

Page 34: ...ption Type CC 1 CC 2 CC 3 CC 4 608 select CC 1 type 608 select CC 2 type 608 select CC 3 type 608 select CC 4 type 708 Caption Type Service 1 Service 2 Service 3 Service 4 Service 5 Service 6 708 select Service 1 type 708 select Service 2 type 708 select Service 3 type 708 select Service 4 type 708 select Service 5 type 708 select Service 6 type ...

Page 35: ...ay Turn off IMD display IMD Color Green Red White IMD character display green IMD character display red IMD character display white IMD protocol TSL3 1 TSL4 0 TSL5 0 Select TSL3 1 Select TSL4 0 Select TSL5 0 IMD name Channel1 IMD name display IMD ID 0 127 The IMD address can be set anywhere between 0 127 The IMD address can be used to set different IMD addresses of ...

Page 36: ...ress when using RS 422 system to remotely control different machines Baud Rate 38400 Select the baud rate for communication 38400 LED Tally ON OFF Turn on LED Tally Turn off LED Tally OSD Tally Mode OFF RG GR RGY Turn off OSD Tally OSD Tally select RG mode OSD Tally select GR mode OSD Tally select RGY mode LED Tally Source GPI TSL Select GPI Select Select TSL protocol control ...

Page 37: ...ese English Menu language selection Chinese Menu language selection English OSD time 5 60 Setting menu display time OSD Position Top left Upper right Bottom left Bottom right Menu position is at the top left Menu position is at the top right Menu position at the bottom left Menu position at the bottom right Factory NO Choose whether to restore ...

Page 38: ...on Key Lock Factory Settings Use this feature you can reset this monitor to factory settings The factory settings can be restored when the following conditions occur on the monitor 1 Press MENU button to enter main menu 2 When the monitor s screen display or sound is not normal you can enter the factory reset option to return to the factory settings in case of non hardware failure ...

Page 39: ... 5 Press the ENTER key to select whether to restore the factory settings Select Yes when prompted 6 Wait for 3 seconds and then press the POWER button to boot the monitor to restore the factory settings is completed Remote Control Remote control the monitor through Ethernet 1 Connected with monitor via LAN and you can achieve remote controlling by software Konvision Device Controller Network remot...

Page 40: ...white blue blue white orange brown white brown 568B standard orange white orange green white blue blue white green brown white brown AC Power Connection Plug the AC power cord into the monitor AC jack Note 1 Please hold the plug tight when you pull out the power cord 2 Please do not connect the power supply before you insert the cable well 3 Please use power cord match to monitors ...

Page 41: ...arts Repairer User Signature Name Qty This warranty card should be filled in immediately when purchasing Please keep a proper record of this warranty card As the continuous improvement of the products this will subject to change without notice All contents on this data have been carefully checked if there is any printing errors omissions or any misunderstanding our Company reserves the right of in...