User Manual
If “CYCLIC” is chosen from the DISPLAY SET menu, multiple values can be rotated
through the front display.
The first line will flash.
Use
▼ and ▲
to navigate to other lines. Press
◙
to enable
or disable each value. This will remove the asterisk, thereby hiding that line from
being shown on the main screen:
*FAN SET
: (Field varies) Shows current active set-point or fan power
*LIQ TEMP
: Shows reservoir liquid temperature
CH1 TEMP
: Shows first external sensor temperature (if connected)
CH2 TEMP
: Shows second external sensor temperature (if connected)
FAN
: Shows radiator fan RPM
*PUMP
: Shows pump impeller RPM
*FLOW
: Shows liquid flow rate through the unit
Press
◄
to return to the previous menu, or press
►
to exit DISPLAY SET.
▲
▼
We hope your Koolance system will provide you with years of reliable cooling
performance. To help avoid unnecessary RMA issues, we have prepared this list
of possible operational problems, and their most common solutions.
1. After filling the reservoir with coolant and turning on the system, there are no
visible signs of liquid movement...
Check the flow meter value (see “DISPLAY SET”). If there is no detected flow
immediately after filling the reservoir, or the flow rate is very low or periodic,
this usually indicates the pump has not finished priming. Open the fill port on
top of the reservoir and temporarily set the pump speed to 10 (see “PUMP
SET”) to help push out the air.
If possible while the pump is running, gently tilt your cold plates or other
components connected to the system in various directions to assist with
bleeding air from the cooling loop. If it becomes necessary to significantly tilt
the unit to assist with priming, close the fill port and power-off the unit before
doing so.
2. The temperature alarm sounds and I’m not sure why...
The offending temperature sensor and value will flash in the front display
whenever an alarm sounds. Check that your currently selected temperature
sensor and alarm are configured as desired (see “TEMP SET” and “ALARM
SET”). If you are certain the cooling system is working properly otherwise, try
resetting all system settings by holding
▼ + ▲ for 3 seconds.
3. My system appears to be leaking fluid or water...
Check that all fittings are properly installed and tightened. This product uses
NPT 1/4in threaded fittings. Plumber’s tape is required to seal the fittings.
4. The front display is locked up or not responding.
Reset all system settings by holding
▼ + ▲ for 3 seconds. After a reset, all
configuration settings (temperature, alarm, fans, etc.) must be updated again.
5. The pump is not operating at lower power level settings.
Due to variations in pumps, the motor may not always operate at the lowest
speed settings. This is more likely to occur if the speed is increased from a very
low level rather than decreased from a higher level. The pump speed must be
kept on a level that allows the motor to operate continuously. Note that during
system power-up, the pump automatically throttles to maximum speed before
dropping to the user’s preset level (to help prevent stalling).
Troubleshooting
The first line will flash. Press
▼ or ▲ to change what this line will display:
FAN SET
: (Field varies) Shows current active set-point or fan power
LIQ TEMP
: Shows reservoir liquid temperature
CH1 TEMP
: Shows first external sensor temperature (if connected)
CH2 TEMP
: Shows second external sensor temperature (if connected)
FAN
: Shows radiator fan RPM
PUMP
: Shows pump impeller RPM
FLOW
: Shows liquid flow rate through the unit
Press
◙
to move to line 2, and similarly use
▼ or ▲ to choose what will be
displayed on the second line. Press
◙
again to exit.
▲
▼
The first option, “FIXED”, will flash.
Press
◄ or ►
to change between these
options. Press
◙
to configure one of the selections,
or press
▲ to exit.
If “FIXED”
is selected, two lines will be shown:
FAN SET 50%
: First line display option
LIQ TEMP 30.5C
: Second line display option
DISPLAY SET
The display settings configure which values you wish to appear on the front display
and how they are shown:
DISPLAY
FIXED CYCLIC
: Show 2 fixed values or cycle multiple values