background image

Superior Liquid Cooling Systems

®

English  v1.02

RP-985, RP-1005

User’s Manual

RP-985, RP-1005

User’s Manual

www.koolance.com

ISO 

9001

Printed in Korea

Summary of Contents for RP-1005

Page 1: ...Superior Liquid Cooling Systems English v1 02 RP 985 RP 1005 User s Manual RP 985 RP 1005 User s Manual www koolance com ISO 9001 Printed in Korea...

Page 2: ...nal use and household use but is not designed developed and manufactured as contemplated for use accompanying fatal risks or dangers that unless extremely high safety is secured could lead directly to...

Page 3: ...with the solution although generally mild Avoid contact as much as possible and wash exposed area with soap and water for at least 15 minutes If irritation persists or if contact has been prolonged g...

Page 4: ...Thru Wire Mounting screws ATX Jumper Wire User Manual Included Hardware flat head screw driver phillips head screw driver pliers scissors Required Tools During installation you may need the following...

Page 5: ...the SET mode select button 1 Temperature sensor 1 is displayed 2 Temperature sensor 2 is displayed 3 Temperature sensor 3 is displayed 4 All temperature sensors are cycled automatically 5 Fan setting...

Page 6: ...al Mode Auto Mode Temperature Range Fan Duty s Fan Power Pump Voltage Pump Power 1 0 35 C 32 95 F 5 20 7 68 60 2 36 37 C 97 99 F 6 24 7 83 62 3 38 39 C 100 102 F 7 28 8 08 64 4 40 41 C 104 106 F 9 36...

Page 7: ...r fan connections 2 0A max per plug 3 0A total TEMP Temperature sensors shown on the front display ATX Wire lead for safety shutdown relay For computer use leave the 2 pin wire connected to NO Normall...

Page 8: ...Connection The temperature sensors andATX lead may come pre connected to your unit If not connect them per the diagram on page 7 Connect a 12 Volt 4 pin Molex plug from the power supply to the power c...

Page 9: ...most loops you don t need to worry about hot water moving from one block to the next It gets only a little warmer throughout the entire loop Generally series is the simplest and most effective config...

Page 10: ...t Block RAM Block HD Block Splitter 10mm 6mm 6mm 6mm 6mm 6mm 6mm Installation Nozzles are designed to attach tightly If you need to remove a hose for any reason it may not pull off easily even after u...

Page 11: ...Please refer to your cooler kit s individual installation instructions then continue on to the next section WARNING The cooling system s pump can not be run dry for any period of time Never power on t...

Page 12: ...d add more liquid when needed If you frequently hear this rushing noise in the future it usually indicates the need for more coolant Replace the fill port on the reservoir Do not overtighten the fill...

Page 13: ...ling performance To help avoid unnecessary RMA issues we have prepared this list of possible operational problems and their most common solutions 1 The pump does not appear to be operating properly Pu...

Page 14: ...ated until you have discovered where the leak is coming from and can repair the problem Should the leak be situated somewhere where it can not be easily repaired please contact our Technical Departmen...

Page 15: ...age resulting from warranty service performed by a non authorized repair service No responsibility is assumed for any special incidental or consequential damages due to a defective Koolance product In...