background image

 

 

 
 
Trouble Shooting

 

 

Issue 

Case 

Solution 

 

The indicator is not on. 
The compressor doses not 
start. 

The plug is loose and is not 
properly connected  

Adjust the plug 

no power 

 
Restore power 

The indicator is on ,but the 
compressor  does  not  run 
and makes a buzzing noise  

 

The power voltage is

98V. 

 
 

Put a power-regulator more 
than 
1000W power together. 

The compressor stops 
very  shortly after starting, 
and  restarts after a few 
minutes,  repeatedly. 

The power voltage is

> 

132V. 

 
 

 

The compressor works 
normally, 
but the cabinet takes too 
long to cool 

The door is opened too 
frequently. 

Reduce open times. 

 
The freezer is 
overloaded or 
food is placed to 
close together 

 

Adjust the placement of the  
product to leave space 
for  p r o p e r  
ventilation of  

 

The frost film is too thick. 

Defrost the unit 
andefrostdefrost. 

The surface of the 
condenser is 
Dirty. 

Clean the 
condenser. 

The door seals badly. 

Adjust the door seal. 

 

 

The noise is too loud 

The freezer is on an 
unstable service 

Move to a stable surface 

The fixing of the freezer is 
loose. 

Tighten the fixing. 

There’s contact 
between  pipes. 

Separate the pipes 

 

 

The following are not issues but are to be expected as normal operation 
of your freezer 

 

  The sound of water flowing during operation is normal; this is the 

refrigerant. 

  When the humidity is high, dew may form on the surface of the freezer 

  When the freezer is running, the condenser and compressor will be hot 

 

 

 

Reviews: