BEAR
IT
Page 34
Er08
Encoder fan error:
Combustion Fan
regulation failed
1. Exhaust fan encoder do not give data
to the electronic board
2. The exhaust fan is stacked or failed
3. The system is not clean periodically
1. Stove will auto switch OFF
2. Reset error with long pressure on
button ON/OFF
3. Clean stove following instruction
4. Try to start stove again.
5. If error appear call service
Er11
Day and time not
correct due to
prolonged absence
of power supply
1. The stove are switched off from
power very long time.
2. The battery on main board are
defective
1. Power ON stove and adjust date
and time
2. If error appear call service to
change main board battery
Er12
Failed ignition
1. To much ash in burning chamber
2. Burning pot are blocked (not clean)
3. The pellet is wet
4. Pellet tank empty
5. Transporter stack and is blocked
1. Clean ash and burning pot.
2. Load pellet in tank
3. Unload all pellet from tank and
clean transporter
4. Check the pellet moisture
5. Reset error with long pressure on
button ON/OFF
6. If error appear call service
Er15
Lack of voltage
supply
1. The voltage are lack for some reason
1. If there is happen lost of power
from supply then reset stove and
start again, if not then
2. Check the stove cable
2. Check the power connection
3. Check the main fuse in house
4. If error appear call service
Er17
Air flow regulator
error
1. Air flow sensor do not send data to
main board or connection cable are fail.
1. Stove will auto switch OFF
2. Reset error with long pressure on
button ON/OFF
3. Try to start stove again if the air
flow sensor is fail the stove will start
using fixed parameters’.
4. Call service if alarm appear again
and even the stove is run (the
system have solution to work till
service come to check)
Er18
Run out of pellet
1. No pellet in tank
1. Stove will auto switch OFF
2. Load pellet in tank
3. Reset error with long pressure on
button ON/OFF
4. If error appear call service
Er39
Air Flow sensor
damaged
1. Air flow sensor are fail
1. Stove will auto switch OFF
2. Reset error with long pressure on
button ON/OFF
3. Try to start stove again if the air
flow sensor is fail the stove will start
using fixed parameters’.
4. Call service if alarm appear again
and even the stove is run (the
system have solution to work till
service come to check)
Er41
Minimum air flow in
Check Up not
reached
1. The rope on door is damaged
2. Stove is not cleaned periodically
3. Air intake pipe are blocked
1. Check the door and rope
2. Clean stove following instruction
3. Check air intake pipe and
complete intake system
4. Reset error with long pressure on
button ON/OFF
5. If error appear call service