BEAR
IT
Page 35
Er42
Maximum air flow
reached
1. The exhaust fan are damaged
2. Stove is not cleaned periodically
3. The exhaust system pipe are blocked
1. Check and change fan
2. Clean stove following instruction
3. Check exhaust pipe and complete
exhaust system
4. Reset error with long pressure on
button ON/OFF
5. If error appear call service
Er44
Open door error
1. Door is open
1. Check the door if open close
2. Check the rope on door
4. Reset error with long pressure on
button ON/OFF
5. If error appear call service
Er47
Auger Encoder
error: no Encoder
signal
1. Auger encoder do not give data to the
electronic board
1. Stove will auto switch OFF
2. Reset error with long pressure on
button ON/OFF
3. Try to start stove again if the
encoder is fail the stove will start
using secunds for controlling data.
4. Call service if alarm appear again
and even the stove is run (the
system have solution to work till
service come to check)
Er48
Auger Encoder
error: auger speed
regulation failed
1. Auger encoder do not give data to the
electronic board
2. The auger motor is stacked or failed
1. Stove will auto switch OFF
2. Reset error with long pressure on
button ON/OFF
3. Check the auger motor
4. Try to start stove again.
5. If error appear call service
Er52
Module I/O I2C error 1. The flat cable connection between
main board and control panel are break
2. The control panel are fail
1. Stove will auto switch OFF
2. Reset error with long pressure on
button ON/OFF
3. Check the flat cable and change if
fail
4. Try to start stove again.
5. If error appear call service
SErU
Service error.
1. It notifies that the planned hour of
functioning is reached. It is necessary to
call for service.
1. Call service
INFORMATION ON DISPOSING (THROWING AWAY) AND
DISMANTLING (PULLING APART) OF THE STOVE
Dismantling and throwing away, or disposing of an old used stove is the sole responsibility of the owner.
The owner of the stove must abide by the regulations in his/her country related to the safety and
environment protection. Dismantling and disposing of the stove may be left to a third party to do if the
third party is a company authorized to collect and dispose of such materials.
NOTICE:
In all cases you must abide by the applicable regulations of the country where the stove is
installed regarding disposal of such materials (things) and, if necessary, report the disposal of such items.
ATTENTION
Dismantling the stove must be done only when the chamber of the stove is not working and when the
stove is unplugged from power (no power supply).
•
pull out all electric parts,
•
throw away the batteries and electronic cards of the remote control in the proper garbage cans in
accordance with the standards.
•
separate the batteries you are keeping from the electric cards,
•
dismantle the stove with the help from an authorized company
ATTENTION
Disposing of the stove in public places poses a serious risk for people and animals. In such cases it is