background image

8

Manually testing cables

1.  Plug the banana plugs of the leads into the corresponding red and black jacks on the front 

panel of the cable tester.

2.  Touch each lead to the corresponding pin on either end of the cable.

3.  A lit LED accompanied by a beep indicates good connectivity and continuity. 

Using test tones

1.  Switch the Cable Test/Tone Test selector on the receiver to the Tone Test position. The power 

LED will glow red.

2.  Insert one of the connectors of the cable into the appropriate jack on the CBT-MF.

3.  Select the amplitude of the test tone on the tone test volume selector (+0 dB, -10 dB,  

or -50 dB.)

Summary of Contents for CBT-MF

Page 1: ...Multi Function Dual Chassis CABLE TESTER User Manual CBT MF...

Page 2: ...have been run through walls or ceilings as well as cables that have been put into audio or home theater installations LED indicators and a beep verify that each pin on the cable is properly connected...

Page 3: ...periods of non use Do not attempt to disassemble or repair the equipment doing so will void the warranty and Kopul will not be responsible for any damage Clean the unit with a soft dry cloth Use only...

Page 4: ...acks Battery compartments underside not shown Pin indicator and continuity LEDs Cable testing jacks LED speed selector Power LEDs Cable test Tone test power selector Tone test volume selector Power sw...

Page 5: ...ttery compartment cover by pressing the locking tab and removing the cover 2 Insert the terminals of the snap connector onto the battery 3 Place the battery into the battery compartment making sure to...

Page 6: ...indicate cable continuity They only indicate that batteries are installed into both sender and receiver 3 Switch the Cable Test Tone Test selector on the receiver to the Cable Test position The power...

Page 7: ...nd receiver can be separated by sliding them apart Connect each side to the cable to be tested 7 The pin indicator LEDs will flash on both sides to show each operator the status of each pin s continui...

Page 8: ...LEDs 1 through 5 The other LEDs will not light up There is good continuity on each pin There is a faulty connection grounding problem short circuit or possibly a broken or damaged wire on that pin Ex...

Page 9: ...nd of the cable 3 A lit LED accompanied by a beep indicates good connectivity and continuity Using test tones 1 Switch the Cable Test Tone Test selector on the receiver to the Tone Test position The p...

Page 10: ...eeve 3 Ring shorted with sleeve Speakon 1 1 2 1 3 2 4 2 Phono 1 screen 2 hot Pin 1 Pin 2 Pin 3 Pin 1 Pin 3 Pin 2 Pin 1 Pin 3 shorted with sleeve 1 Sleeve 3 Ring 2 Tip 3 Ring Pin 1 Pin 3 Pin 2 Pin 1 Pi...

Page 11: ...Test tone amplitude Power 1 25 6 5 6 3 2 16 5 15 2 cm Each chassis W 3 25 8 2 cm 1 4 lb 0 6 kg Speakon 4 pin XLR M F 3 pin XLR M F 5 pin RCA Phono DIN 3 pin 5 pin TRS TRS 3 5 mm RJ45 RJ11 BNC Banana...

Page 12: ...sed by misuse neglect accident alteration abuse improper installation or maintenance EXCEPT AS PROVIDED HEREIN THE WARRANTY PROVIDER MAKES NEITHER ANY EXPRESS WARRANTIES NOR ANY IMPLIED WARRANTIES INC...