background image

 GB 

KORALUX towel rail radiators with electric heating and spatial thermostat

KORALUX towel rail radiators with electric heating of the heat-carrying medium and spatial thermostat (hereinafter referred to only as 
TRR-E

R

) are designed for heating of bathrooms, corridors, toilets and gyms etc. 

When using the radiator for drying textiles, only 

textiles washed in water can be dried!

Description

For heating of the heat-carrying medium, the TRR-E

R

 is fitted with an electric heating element with electronic spatial thermostat EL.07RC. 

An antifreeze mix is used as the heat-carrying medium for filling the TRR-E

R

, which allows for use of the TRR-E

R

 in buildings with an 

anticipated temperature drop below the freezing point (down to –10°C) during the winter.
The electronic thermostat guarantees intelligent operation of the TRR -E

R

. It is equipped with a protective switching relay, which restricts 

switching more frequently than once every 5 seconds. If there is a power failure in the mains network, once the device is switched on again, 
all functions of the thermostat, which were operating at the moment of the power failure, are automatically renewed, including completion 
of the drying cycle. A temperature switch is housed inside the electric heating element with switching temperature of approximately 85°C. 
Once this temperature has been reached, the switch switches off the electric heating element and switches it back on as soon as the heat-
carrying medium cools down to a temperature of approximately 55°C (Fig.1).

!Warning: The surface of the radiator can reach temperatures of more than 80°C when covered!

Installation and positioning

The TRR-E

R

 must always be installed in a vertical position with the electronic thermostat located at the bottom, i.e. under the TRR-E

R

 (Fig. 

2). Fitting of the TRR-E

R

 with thermostat positioned vertically from the top or horizontally is forbidden (Fig. 2)!  

The TRR-E

R

 is supplied with the electronic thermostat dismantled (Fig. 3). Before installing the thermostat, check that the power supply 

cable is not damaged! A damaged thermostat or power supply cable must not be installed! When installing the thermostat, connect the 
cable of the heating part of the electric heating element and the thermostat (Fig. 4). Fit the thermostat to the heating part of the electric 
heating element and secure it by tightening the two side screws using the spanner provided (Fig. 4). Hang the TRR-E

R

 with fitted electric 

heating element onto the wall with the aid of the bracket provided together with the TRR-E

R

. If the TRR-E

R

 is positioned in the corner of a 

room or in an alcove etc., a minimum side distance of the radiator from the wall of 50 mm must be adhered to during installation. The 
distance between the back of the TRR-E

R

 and the wall is given by the dimensions of the brackets supplied with the TRR-E

R

. The TRR-E

R

 

must not be positioned directly under a mains socket. The TRR-E

R

 is not designed for installation in cloakrooms. In order to rule out any 

danger to very small children, it should be installed in such a way that the lowest cross bar is at least 600 mm above the floor. During 
handling and installation, the TRR-E

R

 must be protected against shocks to avoid mechanical damage. During installation, be careful to 

ensure no damage is caused to the power supply cable or the electronic thermostat!
Installation and replacement of the TRR-E

R

 may only be performed by a professional with the appropriate electrical qualifications. A check 

must also be made by a person authorised to do so before the TRR-E

R

 is first connected to the mains to see whether the electrical 

installation meets the requirements of the prescribed safety regulations. In bathrooms and showers, the provisions of the ČSN 33 2000-7-
701 standard (or IEC 60364-7-701) must be complied with. 
The TRR-E

R

 must not be positioned in bathrooms and showers inside the bath or shower or above the bath or shower (Fig. 5). The 

electrical  supply  equipment,  to  which  the  electric  heating  element  will  be  connected,  must  meet  the  requirements  of  regulations  for 
connection of class I appliances of the required power output. In bathrooms and shower areas, the electrical supply equipment must 
include the appropriate RCD and the provisions of the ČSN 33 2000-7-701 standard (or IEC 60364-7-701) must be met. When installed 
outside of the Czech Republic, the relevant national regulations must be complied with. The electric heating element is connected to the 
mains junction box. Use of a mains plug and extension cable is forbidden (Fig. 7)!

Colours of wires in the power supply cable

: L -  black (brown), N – blue, PE - green/yellow (Fig. 4)

Cleaning and maintenance

Regular detergents designed for cleaning painted surfaces can be used to clean the outer surface of the radiator. Always clean the TRR-

ER

 when it is safely disconnected from the mains and leave it to dry before switching it back on. Make sure that no water gets into the 

electrical parts and the electrical supply equipment. You must not interfere in the construction of the TRR-E

R

 in any way. Dismantling or 

loosening the blanking plugs and electric heating element is explicitly forbidden (Fig. 6).

Operation

The TRR-E

R

 is set into operation by turning the control knob of the electronic thermostat from the off position 

     

 

 

in the direction of position 

    

     

      

, which is the range of the required ambient air temperature (Fig. 8). The indicator will be lit red until the set temperature is reached. 

Once the set temperature is reached, the indicator will light up green. Press the control knob in an upwards direction (Fig.8) to switch on the 
“drying” programme, during which the TRR-E

R

 will heat for a period of two hours regardless of the external air temperature, the indicator is 

lit  orange.  Once  the  “drying”  programme  has  ended,  the  thermostat  will  switch  the  TRR-E

R

  back  to  the  originally  set  temperature 

regulation. If you want to end the drying programme early, press the control knob in an upwards direction again to end the “drying” 
programme and switch the TRR-E

R

 back to the originally set temperature regulation.

Switch off the TRR-E

R

 by turning the control knob to the 

    

  

 position. When the thermostat switches off, the indicator will go out.

Operating indications – indicator status

Green    

- the device is switched on, it is not heating, the temperature in the room is higher than the 

  

temperature set on the thermostat   

Red  

 

- the device is operating, heating 

Orange  

 

- the device is operating, heating in “drying” mode

Flashing 

 

- error state, the manufacturer recommends switching the device off for a period of 1 minute and 

  

then switching it back on. If the defect persists, contact the manufacturer's technical service 

  

department.

Unlit 

 

- the device is switched off (or there is no power supply to the device)

Summary of Contents for KLCER 1220.450

Page 1: ...KLTER 1220 500 KLTER 1220 600 KLTER 1220 750 KLTER 1500 450 KLTER 1500 500 KLTER 1500 600 KLTER 1500 750 KLTER 1820 450 KLTER 1820 500 KLTER 1820 600 KLTER 1820 750 900 450 500 600 750 450 500 600 750...

Page 2: ...1 3 5 6 7 2 4 2 85 C OFF ON 55 C L N PE 1 2 3 3 4 672081845 005 01 225cm 60cm 6 0 c m IEC 60364 7 701 OFF 30 C 120 P max 2h OFF ON 8 9 10...

Page 3: ...m p ipojen m do elektrick s t mus osoba k tomu opr vn n prov it zda elektrick instalace spl uje p edepsan bezpe nostn p edpisy V koupeln ch a sprch ch mus b t dodr ena ustanoven normy SN 33 2000 7 70...

Page 4: ...av c pro tyto ely pro kolena v robcem OTT ER Pokud je p vodn kabel po kozen ihned odpojte el top t leso od p vodn el s t a zajist te odbornou opravu V p pad zji t n niku teplonosn l tky z otopn ho t l...

Page 5: ...u boden installiert ist Bei der Handhabung und Montage ist der BHK ER vor Sto zu sch tzen damit es nicht zu seiner mechanischen Besch digung kommt Bei der Montage ist darauf zu achten dass es nicht zu...

Page 6: ...wecke durch den Hersteller des BHK ER geschult ist Falls das Anschlusskabel besch digt ist ist der Elektroheizstab umgehend vom Stromnetz zu trennen und eine fachgerechte Reparatur sicherzustellen Fal...

Page 7: ...age is caused to the power supply cable or the electronic thermostat Installation and replacement of the TRR ER may only be performed by a professional with the appropriate electrical quali cations Ac...

Page 8: ...the electric heating element must be immediately disconnected from the mains supply and repair arranged with the manufacturer Fig 9 If there is any leakage of the heat carrying medium there is a dang...

Page 9: ...lektrickej siete mus osoba na to opr vnen preveri i elektrick in tal cia sp a predp san bezpe nostn predpisy V k pe niach a sprch ch musia by dodr an ustanovenia normy SN 33 2000 7 701 resp IEC 60364...

Page 10: ...na tieto ely vy kolen v robcom VRT ER Pokia je pr vodn k bel po koden ihne odpojte el vykur teleso od pr vodnej el siete a zaistite odborn opravu V pr pade zistenia niku teplonosnej l tky z vykurovac...

Page 11: ......

Page 12: ...gten Eigenschaften unter der Voraussetzung einhalten wird dass es auf die in dieser Anleitung beschriebene Art und Weise montiert und verwendet wird Die Garantie bezieht sich nicht auf mechanische Bes...

Reviews: