General installation guide for Korax Solar photovoltaic modules

   

               

INTRODUCTION 

 

This  guide  contains  application  and  safety  information  with  which  you  should  be  familiar  before  using  your  Korax  Solar  photovoltaic  module.  Your 
authorized Korax Solar distributor or dealer can provide additional sizing and system design information if necessary. 
 
The information in this guide is based on Korax solar knowledge and experience and is believed to be reliable, but such information including product 
specifications  and  suggestions  do  not  constitute  a  warranty,  expressed  or  implied.  Korax  solar  reserves  the  right  to  make  changes  to  the  product 
specifications, or guide without prior notice. 

 

GENERAL INFORMATION 

 
The installation of modules requires a great degree of skills and should (if DC voltage exceeds 100 V then must) only be performed by qualified licensed 
professional,  including  licensed  contractors  and  licensed  electricians.  The  installer  assumes  the  risk  of  all  injury  that  might  occur  during  installation, 
including the risk of electrical shock. 
 
Korax Solar photovoltaic modules do not require the use of special cable assemblies. All modules come with a permanently attached junction box that 
will accept a variety of wiring applications or with a special cable assembly for ease of installation. 
 
It is recommended to utilize qualified installer or reseller for service.

 

 

WARNING 

 

All instructions should be read and understood before attempting to install, wire, operate, and maintain the module. Contact with electrically active parts 
of the module such as terminals can result in burns, sparks, and lethal shock whether the module is connected or disconnected. 
 
Modules  produce  electricity  when  sunlight  or  other sources  illuminate  the module  is  not considered  a  shock  hazard. When modules  are  connected  in 
series,  voltages  are  additive.  When  modules  are  connected  in  parallel,  current  is  additive.  Consequently,  a  multi  module  system  can  produce  high 
voltages and current, which constitute an increased hazard and could cause serious injury or death.  

 

TECHNICAL INFORMATION 

 

The Korax Solar photovoltaic modules use high efficiency pseudo-square monocrystalline (or square polycrystalline) silicon cells to turn solar radiation 
energy into direct current electric current.  The cell circuit is laminated using ethylene-vinyl acetate (EVA) as a capsulant, in an assembly formed by a 
tempered glass at its front and plastic polymer (Tedlar) at the rear, which provides resistance against environmental agents and electric insulation. 
 
The  laminate fits into  an  anodised  aluminium structure.  The IP-65 protected terminal  boxes  are made  from  temperature  resistant  plastic  and  contains 
terminals,  connection  terminals  and  protection  diodes  (by-pass  diodes).  The  frame  has  several  fasting  holes  for  securing  the  module  to  the  support 
structure and its earthing, if necessary.

 

 

 

 

Section of a photovoltaic module. 

 

The  electrical  values  are  obtained  under  standard  testing  conditions  (STC)  which correspond  to  a  1000 W/m

2

  irradiance,  1,5  AM  (air-mass) spectrum 

and  25 

o

C  cell  temperature.  However,  the  actual  working  conditions  of  the  modules,  once  they  are  installed  may  be  different  from  the  laboratory 

conditions. Therefore it is advisable to check out the actual local conditions in order to carry out the pertinent corrections in calculation. 
 
Under actual conditions, a photovoltaic module may experience higher than standard illumination and produce more current and voltage than reported at 
STC  conditions.  Accordingly  the  values  of  Isc  and  Voc  should  be  multiplied  by  a  factor  of  1.25  when  determining  the  voltage  ratings,  conductor 
capacities, fuse sizes, and sizes of controls connected to the module output.  

 