Module installation and operation should be performed by qualified personnel only. Children should not be allowed near the solar electric 

installation. 

 

If not otherwise specified, it is recommended that requirements of the local, national or regional electrical codes be followed. 

 

Use module for its intended function only. 

 

Do not disassemble the module, or remove any part or label installed by manufacturer. 

 

INSTALLATION 

 

Series and parallel wiring 

Modules can be wired in series to increase voltage. Connect wire from the positive terminal of one module to the negative terminal of the next module. 
The  first  illustration  shows  four  modules  connected  in  series.  Installer  should  consider  the  maximum  allowed  system  voltage  in  case  of  connecting 
modules in series. Take also care of connecting in series strictly only modules of the same type (the current at the maximum power point must be the 
same).  

 

Connect modules in parallel to increase current. Connect wires from the positive terminal of one module to the positive terminal of the next module. The 
second illustration shows four modules connected in parallel. 
 
It is recommended that paralleling modules be performed using an external junction box. Installer should also keep in its mind that the current values are 
additive in parallel connection and the common wire cross section must be chosen according to local regulations and standards. When cabling a system 
of several modules installer should ensure that the voltage drop on the main conductor does not exceed 2 % of the nominal voltage. 
 
There are many types of mounting system used to install Korax Solar modules. The mounting structure must withstand all snow and wind forces. Module 
mounting holes are provided for easy installation and proper mechanical loading. Contact your local dealer for information regarding mounting structures 
and special mounting profiles for modules. This illustration shows one possibility to mounting some modules. 

 

Grounding 

Module  frames  should  be  connected  to  an  earth  for  safety  and  protection  from  lighting.  Korax  Solar  modules  have  a  hole  on  the  frame  marked  with 
symbol  for  connecting  the  earthing  cable.  If  the  support  structure  is  a  conductor,  the  metallic  contact  between  the  frame  and  the  structure  must  be 
ensured during the assembly of the modules. In that case the supporting structure must earthed according to the local regulations. Should the support 
structure made  of  non-conducting material  it  is  recommended that the  earth  conductors from  the  individual modules  connected  to  a  common  earthing 
terminal (bus conductor) so that removal of any module does not interrupt the earth connection of the remaining modules. 

 

 

Air Circulation 

Sufficient clearance between the module frame and the mounting surface is required to allow cooling air to circulate around the back of the module. This 
also allows any condensation or moisture to dissipate. 