background image

Korenix 

JetNet 3508-LVDC/ JetNet 3508G-LVDC 

11 

 

(Table 1) 

Summary of Contents for JetNet 3508-LVDC

Page 1: ...Korenix JetNet 3508G LVDC Series JetNet 3508 LVDC 3508G LVDC Industrial Ethernet Switch User s Manual Version 1 0 www korenix com ...

Page 2: ...1 Korenix JetNet 3508G LVDC Series JetNet 3508 LVDC 3508G LVDC Industrial Ethernet GbE Switch Copyright Notice Copyright 2019 Korenix Technology Co Ltd All rights reserved Reproduction in any form or by any means without permission is prohibited ...

Page 3: ...uct Features 4 2 Hardware Installation 5 2 1 Hardware Introduction 5 Dimensions 5 Front Panel 7 Connector definition 8 LED Indicators 9 2 2 Wiring the Power Inputs 9 2 4 Wiring Earth Ground 10 2 5 Rotary Switches Ignition Function 10 3 Appendix 13 3 1 Product Specification 13 3 2 Revision History 15 ...

Page 4: ...DC 3 1 Introduction Korenix JetNet 3508G LVDC Series is a power over Ethernet rail switch that is specially designed for industrial or commercial applications The following topics are covered in this chapter 1 1 Overview 1 2 Product Features ...

Page 5: ...arge image traffic but also support CoS to adjust the priority of data transmission The compact size with IP 41 steel metal case allows JetNet 3508G LVDC series to be reliably operated in 40 75 extreme environment 1 2 Product Features Korenix JetNet 3508 LVDC 3508G LVDC have the following features JetNet 3508 LVDC JetNet 3508G LVDC Features Highlight 10 100 TX port 7 10 100 1000 TX port 1 8 Class ...

Page 6: ...Korenix JetNet 3508 LVDC JetNet 3508G LVDC 5 2 Hardware Installation 2 1 Hardware Introduction Dimensions JetNet 3508 LVDC dimensions 116 H x 146 W x 58 D ...

Page 7: ...Korenix JetNet 3508 LVDC JetNet 3508G LVDC 6 JetNet 3508G LVDC dimensions 116 H x 146 W x 58 D ...

Page 8: ...Net 3508G LVDC 7 Front Panel JetNet 3508 LVDC 3508G LVDC include system power LED x1 and 8 LEDs for the port operating status JetNet 3508 LVDC JetNet 3508G LVDC Don t have PoE LED Lnk Act LED PWR LED Power Ignition Ignition Input ...

Page 9: ...Korenix JetNet 3508 LVDC JetNet 3508G LVDC 8 Connector definition ...

Page 10: ...System Standby Off No Power Input Lnk Act Green on The port is attached with partner Green Blinking The port is transmitting or receiving packets Off The port s link is inactive 2 2 Wiring the Power Inputs JetNet 3508 LVDC 3508G LVDC power input is 9 36VDC IMPORTANT Do make sure that different models must connect to the corresponding supply voltage Guarantee will not apply to the damage caused by ...

Page 11: ...ction between the JetNet 3508 LVDC JetNet3508G LVDC and earth ground to avoid system damage in below photo 1 On the right side of bottom of the JetNet 3508 LVDC JetNet3508G LVDC there is one earth ground screw 2 Loosen the earth ground screw with a screwdriver 3 Tighten the screw after the earth ground wire is connected 2 5 Rotary Switches Ignition Function 4 Pin rotary switch is one of components...

Page 12: ...Korenix JetNet 3508 LVDC JetNet 3508G LVDC 11 Table 1 ...

Page 13: ...Korenix JetNet 3508 LVDC JetNet 3508G LVDC 12 Diagram 1 ...

Page 14: ...re and Forward technology with 16Gbps non blocking JetNet 3508G LVDC Store and Forward technology with 3 4Gbps non blocking JetNet 3508 LVDC System Throughput 23 8Mega packets per second 64Bytes packet length Transfer packet size 64Bytes 1518Bytes MAC Address 16K MAC address table Packet Buffer 2 Mega bits shared packet buffer Broadcast storm control Default enabled Traffic threshold 25M bps 1000M...

Page 15: ...Female JetNet 3508 LVDC M12 X Conductor 1 0P D1 2 0N D1 3 1P D2 4 1N D2 5 3P D4 6 3N D4 7 2N D3 8 2P D3 Power M12 A Code 5 pin Male LED Indicators Port 1 8 Link Green on Activity Green Blinking Power System Power Ready Green on Ignition function Activity Green Blinking Power Requirement System Power Input voltage DC 12V or DC 24V variation range DC 9 36 V Power consumption 6 Watts DC 24V without P...

Page 16: ...dard EN50155 EN 50121 4 EN50121 3 2 Traffic E mark E13 10R 05 14802 EMC EMI EN50121 3 2 FCC Class A IEC EN61000 6 4 EMS EN50121 3 2 EN50121 1 IEC EN61000 6 2 IEC EN61000 4 2 IEC EN61000 4 3 IEC EN61000 4 4 IEC EN61000 4 5 IEC EN61000 4 6 IEC EN61000 4 8 IEC EN61000 4 9 Variation Shock IEC 61373 Free Fall IEC 60068 2 32 with package Note 1 MTBF hrs 379 940 Warranty 5 Years 3 2 Revision History Edit...