34
Note: Most of the SFP transceivers provide vendor information which allows your switch to
read it. Korenix can display vendor name, wave length and distance of all Korenix SFP
transceiver family. If you see Unknown info, it may mean that the vendor doesn’t provide
their information or that the information of their transceiver can’t be read.
4.3.3 Rate
Control
Rate limiting is a form of flow control used to enforce a strict bandwidth limit at a port. You
can program separate transmit (Egress Rule) and receive (Ingress Rule) rate limits at each
port, and even apply the limit to certain packet types as described below.
Packet type
: You can select the packet type that you want to filter. The packet types of the
Ingress Rule listed here include
Broadcast Only
/
Broadcast/multicast
/
Broadcast/Multicast/UnknownUnicast
and
All
. The packet types of the Egress Rule
(outgoing) only support
All
packet types.
Rate
: This column allows you to manually assign the limit rate of the port. Valid values are
from 1Mbps-100Mbps for fast Ethernet ports and gigabit Ethernet ports. The step of the
rate is 1Mbps. Default value of Ingress Rule is “8” Mbps; default value of Egress Rule is 0
Mbps. 0 stands for disabling the rate control for the port.
Click on
Apply