Saving and loading data
En-
26
9. Use
“.KSC
Allocation”
to
specify
how
the
sample
data
will
be
loaded,
and
whether
or
not
existing
sample
data
will
be
erased.
Append
will
leave
all
currently
‐
loaded
Sampling
Mode,
User
Sample
Bank,
and/or
EXs
data
intact.
Sampling
Mode
Multisamples
and
Samples
will
be
loaded
into
the
next
available
vacant
numbers
following
the
existing
data.
Clear
Sampling
Mode
Data
will
erase
all
Multisamples
and
Samples
from
Sampling
Mode,
and
load
the
data
in
the
same
configuration
with
which
it
was
saved.
Existing
EXs
and
User
Sample
Bank
data
is
left
intact.
Clear
All
is
similar
to
Clear
Sampling
Mode
Data
,
above,
but
also
un
‐
loads
existing
EXs
and
User
Sample
Bank
data
before
loading
the
new
.KSC
file.
This
frees
up
the
most
memory
for
the
new
.KSC.
You
can
use
the
information
at
the
bottom
of
the
dialog
box,
including
Memory
Required
,
(Memory)
Available
,
and
Enough
slots
for
Samples
&
MS
,
to
determine
whether
or
not
you
need
to
free
up
room
for
the
new
.KSC.
10.Set
the
Load
Method
as
desired.
This
sets
the
preferred
way
to
load
the
EXs
and
User
Sample
Bank
data
in
the
KSC:
load
them
into
RAM,
use
Virtual
Memory,
or
use
the
setting
stored
in
the
KSC.
If
the
KSC
has
no
EXs
or
User
Sample
Bank
data,
this
will
be
grayed
out.
11.Press
the
OK
button
to
load
the
data.
Never
disconnect
USB
devices
or
remove
data
‐
storage
media
while
loading
or
saving.
When
loading
Programs,
Combinations,
Songs,
Set
Lists,
Drum
Kits,
Wave
Sequences,
or
KARMA
User
GEs,
make
sure
that
the
Global
Basic
Setup
page’s
Memory
Protect
settings
are
turned
off
(unchecked).
If
they
are
on,
you
won’t
be
able
to
load
the
data.
Loading individual banks from a .PCG file
1. Go
to
the
Load
page.
2. Select
the
.PCG
file
containing
the
data
you
want
to
load.
3. Press
the
Load
button.
4. Set
the
.PCG
Contents
to
load
the
desired
individual
banks.
5. Select
the
bank
to
load
into
via
the
“To”
parameter.
Automatic reference correction
If
you
set
.PCG
Contents
and
To
to
different
banks,
any
references
in
the
data
will
be
updated
to
match
the
new
bank.
For
instance,
let’s
say
that
you’re
loading
from
the
PCG’s
Bank
I
‐
A
into
Bank
U
‐
G.
If
the
PCG’s
Combinations
used
Programs
from
Bank
I
‐
A,
they
will
be
updated
to
the
use
the
Programs’
new
locations
in
Bank
U
‐
G.
The
same
is
true
for
any
Drum
Kits
or
Wave
Sequences
used
by
Programs.
If
you’re
loading
sequencer
data
at
the
same
time
(with
Load
.SNG
too
checked),
any
Program
and
Bank
Change
messages
within
the
Songs
will
also
be
corrected.
Loading multiple files at once
You
can
select
two
or
more
files
at
once,
and
load
them
in
a
single
operation.
To
do
so:
1. Press
the
Multiple
Select
check
‐
box
at
the
bottom
of
the
screen,
so
that
it’s
enabled.
This
can
be
handy
for
loading
multiple
sample
files
at
once,
importing
banks
of
DX
sounds,
and
so
on.
Multiple
Select
works
for
other
disk
operations
as
well,
including
Delete
(so
be
careful!).
Note
that
when
Multiple
Select
is
on,
you
can’t
change
to
a
different
directory.
When
you’re
done,
turn
it
off
again.
You
can
also
use
“wild
cards”
to
select
multiple
files.
For
more
information,
see
under
the
menu
command
in
the
PG’s
Disk
chapter.