background image

into setting mode, battery unit “AH” &“SET”is flashing, modify the data 
through K1/K2, press one time, battery capacity will be up/down 10Ah,the 
maximum is 5000,the minimum is 50; Press k3 for saving or K4 for back to 
the reading status.   

4.3.4 

  charging mode modify

while on displaying Voltage of solar module, press 

K3 

into setting mode, “SET”&“

” is flashing

press K1/K2 to select 

PWM—

 or ON/OFF

mode

K3 for saving modify or K4 for back 

to reading mode

 

4.3.5  While in the discharging mode, the strip of battery

 will be decreased 

dynamically. While in the charging mode, the strip of the battery will be 
increased accordingly. While there is on the balanced condition or no 
charging/discharging, the strip of the battery is the battery capacity, one strip 
is equal to 10% of the battery.

 

 

5  Security and protections 

The controller has the protections against over voltage, over current, short circuit and 
TVS lightning proof 
Note: lightning proof is the last protection of the controller

In  those areas where 

lightning is quite often, use professional lightning proof system. Without the lightning 
proof system, guarantee will be void, if it’s damaged by the lightning.   
Make sure of proper cooling while installation. 
 

6 Guarantee & customer service   one year warranty, or contact your 

authorizied distributor.  

 
 
 
 
 
 
 

7 Specifications  

Type   

EPIP-40 /20A(I) 

EPIP-40 /30A(I) 

EPIP-40 /40A(I) 

Rated charging current 

20A(max26A) 

30A(max39A) 

40A(max49A) 

Rated load current

Ie

 20A 

30A 

40A 

Over load, short circuit 

protection  

1.25 times of Ie for 60secs

1.5 times of Ie by for 5secs overload protection

2 time of Ie short circuit protection 

Self consumption   

Control mode

<10 mA

  LED & LCD display

MAX

<10mA

,合计(

MAX

 

<20mA 

System voltage 

12/24V AUTOWORK

 

Work temperature 

industrial

I series

):

-20

 to +50

 

Battery capacity 

Battery in parallel from 50AH to 5000ah   

Boost charging   

14.8V

×2/24V

 

equalizing charging 

14.4V; ×2/24V

 

Float charging   

13.4V; ×2/24V

 

Temperature 5mv/

/2v;   

Over discharge voltage 

11.1V

 ×2/24V

 

Control mode 

PWM charging mode & ON/OFF mode for options, control point voltage is 

the intelligent compensation modify of the battery.   

Address:RM.608, Sangdaewon-dong #513-15, 

Seonqanam City, Korea        

TEL:031-777-1588      FAX:031-777-1587     

Email:solar@solar.kr  Website:www.kkkk.com 

 

KORINS INC..

 

 

 

 

 

 

 

 

 

 

 

 

Reviews: