14
Summer mode (only with active cylinder's function)
To switch to summer mode press (when in main view of winter mode). This mode
is available only if the boiler co-operates with the DHW cylinder. Heating medium is
directed to cylinder’s coil. When icon
is on and icon
is off it shows that the
boiler operates in summer mode. In this mode control panel displays pictograms that
describe current boiler's operation mode- digital display indicates heating medium's
temperature.
Pressing
button shifts to preview of current parameters and settings of boiler's
operation in the following order:
-
preview and adjustment of water temperature in DHW cylinder (indicators D and N
on). Water temperature in the cylinder is displayed only when WE-019/01 sensor
is plugged to entry Thw. Pressing
or
buttons when water temperature in
cylinder is indicated on the display results in temperature adjustment- regulation
range: 30 - 80°C (indicators D, N, F on). Setting 0°C blocks boiler's heating on
DHW cylinder which is indicated by flashing icon
,
-
inlet temperature (indicators D and K on),
-
outlet temperature (indicators D and L on),
-
outside temperature (indicators D and G on),
-
flow of the medium through the boiler ( indicator B on),
-
pressure in CH installation (indicator A on),
-
activated power (indicator C on).
If the buttons are not used for 1 minute the display returns to general view mode.
Pressing button during preview or adjustment of parameters results in immediate
return to display's general view mode.
Optimal adjustment of heating medium temperature in accordance with outside
temperature parameters and building's parameters results in low exploitation costs
(reduced power consumption).