17
GB-096B_f.
Technical data
Max. pressure
MPa
0,3 (3 bar)
Min. pressure
MPa
0,05 (0,5 bar)
Outlet temperature
°C
20 ÷ 85
Max. temperature
°C
100
Dimensions (height x width x depth)
EKCO.LN2M
mm
710 x 418 x 252
EKCO.L2M
710 x 418 x 153
Wight
EKCO.LN2M
kg
~24,5
EKCO.L2M
~17,2
Boiler's connections
G 3/4" (internal thread)
Expansion vessel
EKCO.LN2M
l
6
Safety class
IP 22
Rated power
kW
4
6
8
4
6
8
12
Rated voltage
230V~
400V 3N~
Rated current
A
17,4
26,0
34,8 3x5,7 3x8,7 3x11,7 3x17,3
Min. power supply cable cross-section
mm
2
3x2,5
3x4
3x6
5x1,5
5x2,5
Max. power supply cable cross-section mm
2
3 x 25
5 x 25
Max. allowed network impedance
Ω
0,27
0,17
0,15
0,27
Rated power
kW
15
18
21
24
30
36
Rated voltage
400V 3N~
Rated current
A
3x21,7 3x26,0 3x30,3 3x34,6 3x43,3
3x52
Min. power supply cable cross-section
mm
2
5 x 2,5
5 x 4
5 x 6
5 x 10
Max. power supply cable cross-section mm
2
5 x 25
Max. allowed network impedance
Ω
0,27
0,22
0,13
0,11
0,09