9
GB-096B_f.
Advanced settings
For advanced settings switch the control panel to stand-by mode (press and hold button
for approximately 3 seconds) then press and hold button
, and for a short period
of time press
and let go.
To select parameter press
to change the value press
or
:
-
boiler power - enter rated power (kW) as indicated on identification label,
-
pump's working mode:
•
PA- automatic,
•
PC- constant.
-
pump's efficiency [E]:
•
E3.0 - 3.0m,
•
E4.0 - 4.0m,
•
E5.0 - 5.0m,
•
E5.0 - 5.0m,
•
E7.0 - 7.0m,
•
E7.5 - 7,5m.
-
pumpe press mode [PPn]:
•
constant pressure difference (pressure indicator- on),
•
variable pressure difference (pressure indicator- flushing).
-
number of active heaters [AH].
-
DHW cylinder function [DHW function start up]:
•
0- off,
•
1- on,
-
maximal temperature of CH installation,
-
heating curve coefficient, weather compensation switch off:
•
C = 4 - 25,
•
C = 0 - weather compensation switched off, manual regulation of installation's
temperature.
-
heating curve offset:
•
o = -9°C ÷ 9°C.