13
Pic.11. Assamble of flow sensor DN15 200.915101 (18) - date of production after 29-03-2011.
Clips
Attention! The flow sensor should be mounted as shown below. Set the type of sensor in
the service menu,.
Incorrect installation of the flow sensor, and the incorrect setting in the service menu can
result to incorrect measurement of flow and malfunction of the boiler
Attention! On 13-07-2011 was change in build construction. Flow sensor HubaControl DN15
200.915101 (18) was replaced with flow sensor HubaControl DN15 200.715111N (44). This
change led to remove return temperature sensor (20) and introduction an another wire ()
from flow sensor to control panel (17).