background image

27

Pos.

Service code

Picture no.

Name

Amount 

(pcs)

Notice

1

01642

EKCO.L2-02.00.00/010 Heating box EKCO.L2 8kW/230V

1

01184

EKCO.L2-02.00.00/001 Heating box EKCO.L2 12kW/400V

01185

EKCO.L2-02.00.00/002 Heating box EKCO.L2 15kW/400V

01186

EKCO.L2-02.00.00/003 Heating box EKCO.L2 18kW/400V

01187

EKCO.L2-02.00.00/004 Heating box EKCO.L2 21kW/400V

01188

EKCO.LN2-04.00.00

Heating box EKCO.L2 24kW/400V (copper 6 heating elements)

3

01179

EKCO.L2-01.00.00

Front cover EKCO.L2

1

4

01180

EKCO.L2-09.00.00

Bottom wall EKCO.L2

1

5

01181

OK.B7-00.00

Case EKCO.L2

1

6

OK.B3-01-05

Bottom suport case EKCO.L2

1

DC01A

7

01332

EKCO.L2-15.00.00

Safety valve 3 bar pipe

1

Production date after 29-03-2011

8

01173

EKCO.L2-03.00.00

Safety valve 3 bar pipe

1

Production date before 29-03-

2011

9

01174

EKCO.L2-05.00.00

Outlet connection pipe

1

01419

Outlet connection pipe

1

conex connection

10

01175

EKCO.L2-06.00.00

Inlet connection pipe

1

01418

Inlet connection pipe

1

conex connection

11

01176

EKCO.L2-07.00.00

Nodes pipe

1

Construction change after 29-

03-2011

12

01177

EKCO.L2-08.00.00

Pump pipe

1

Production date before 29-03-

2011

13

01178

EKCO.L2-11.00.00

Expansion vessel pipe

1

Production date before 29-03-

2011

14

00853

Expansion vessel

1

15

01331

EKCO.L2-16.01.00

Inner pipe of power board EKCO.L2

1

Power board pipe

16

01183

PCA-ZM.60/02

Power board EKCO.L2

1

17

01182

PSK.P5-00.00.00

Control panel PSK.P5

1

01338

Control panel PSK.P5 EHC

1

18

01212

Flow sensor DN15 200.915101 EKCO.T/TM

1

19

01229

Flow sensor

1

before 13-07-2011

20

00790

WE-005/09

Return temperature sensor NTC

1

before 13-07-2011

21

00791

WE-005/-2

Flow temperature sensor NTC

1

22

01541

WE-029//03

Flow temperature sensor NTC (clip type)

1

after 11-08-2014

23

01194

Electronic pressure sensor

1

24

01195

Differential pressure relief valve

1

25

00001

Automatic air-vent

1

26

00144

Diaphragm safety valve MSL 30.1/2"

1

3Bar

27

00516

WT3a-00.00.00/02

WT-3 safety cut-out EKCO.L2N

1

C.O.  100°C

00489

WT3a-00.00.00/03

WT-3 safety cut-out EKCO.L2Np

1

Under floor heating 75°C

28

01246

Pump EKCO.L2 

Power 4-8 kW

01247

Pump EKCO.L2

Power 12-24 kW

01766

Pump UPM3 Flex AS 15-70 130 AZJ

Electronic pump

30

01294

Magnetic filter F-MAG 3/4

1

31

Z-216

Sleeve 3/4"

2

Flow sensor

32

Z-217

Nipple 3/4"

2

Magnetic filter

34

01270

O-ring seal 17,86x2,62 70NBR

35

00253

Gasket 1.5x14,8x8 (3/8")

1

36

00255

Gasket 1.5x18,2x11,7 (1/2")

1

37

00882

Gasket 1.5x16x24 (3/4")

7

38

00647

Gasket 2x30x21 (1")

2

39

Wing nut M4

2

40

Screw TW 4,1x12 KB-1

1

41

Screw TW 4,1x16TX

2

42

Screw M4x10-5,8-A-Fn/Zn5

4

43

Screw WP M4x10Zn

6

44

01339

Flow sensor DN15 200.915101 EKCO.L2 (with inlet temp. sensore)

1

Change after 13-07-2011 - flow 

sensor with integrated inlet temp. 

sensor

45

01340

P6-H/01

Flow sensor wire EKCO.L2 (with inlet temp. sensore) 6x AWGH28

1

7.  Spare parts list.

Table 2. Parts list.

Summary of Contents for EKCO.L2N

Page 1: ...1 KOSPEL S A KOSZALIN ul Ol cho wa 1 SERVICE MANUAL EKCO L2N EKCO L2Np EKCO L2NF 14 03 2016...

Page 2: ...C H temperature settings 15 3 d D H W cylinder settings 15 3 e Service menu 16 3 1 Connecting of external devices to the control panel PSK P5 17 Pic 13 Connecting of external devices 17 4 Heating box...

Page 3: ...3 5 01181 3 01179 4 01180 17 01182 1 Exterior view of boilers Pic 1 Exterior view 14 01168 Part number in table of parts Service code...

Page 4: ...Service manual EKCO L2N 4 1 1 Exterior view open case 39 3 01179 4 01180 Pic 2 Boiler with open case flow sensor Kospel date of production before 29 03 2011...

Page 5: ...5 Pic 3 Boiler with open case flow sensor Huba Control date of production after 29 03 2011 39 3 01179 4 01180...

Page 6: ...w sensor Kospel date of production before 29 03 2011 2 Construction of boilers 25 00001 35 00253 27 00516 100 C 00489 o 75 C o 21 00791 Tout 20 00790 Tin 17 01182 9 01174 1 Ta 18 ble on page 16 01183...

Page 7: ...er 29 03 2011 25 00001 35 00253 27 00516 100 C 00489 75 C 27 20 00790 Tin 17 01182 9 01174 1 Table page 18 16 01183 37 00882 37 00882 37 00882 37 00882 37 00882 32 34 01270 15 01331 Tout 21 00791 Tout...

Page 8: ...re 29 03 2011 28 Table page 27 38 00647 8 01173 Tout Tin 38 00647 37 00882 10 01175 37 00882 30 01294 37 00882 12 01177 38 00647 37 00882 23 01194 24 01195 37 00882 11 01176 36 00255 37 00882 9 01174...

Page 9: ...0882 30 01294 37 00882 23 01194 24 01195 37 00882 11 01176 9 01174 26 00144 36 00255 18 01212 lub 01339 after 13 07 2011 20 00790 22 01541 after 11 08 2014 34 01270 37 00882 37 00882 32 16 01183 37 00...

Page 10: ...nual EKCO L2N 10 2 2 Construction of boilers view of expansion vessel 14 00853 13 01187 37 00882 36 00255 37 00882 6 32 31 Pic 8 View of expansion vessel flow sensor Kospel date of production before 2...

Page 11: ...11 Pic 9 View of expansion vessel flow sensor Huba Control date of production after 29 03 2011 14 00853 37 00882 6 32 18...

Page 12: ...date of production after 29 03 2011 Attention The flow sensor should be mounted as shown below Set the type of sensor in the service menu Incorrect installation of the flow sensor and the incorrect s...

Page 13: ...the flow sensor and the incorrect setting in the service menu can result to incorrect measurement of flow and malfunction of the boiler Attention On 13 07 2011 was change in build construction Flow se...

Page 14: ...k out the following working parameters by pressing the button A display shows in sequence medium temp setting D and M indicators are on inlet temp D and K indicators are on outlet temp D and L indicat...

Page 15: ...free voltage entry room thermostat connection point Work without room thermostat need to use a jumper Tzas DHW temperature sensor or DHW thermostat connection Set type of sensor in service menu or tak...

Page 16: ...ment 4 Boiler work mode no normal mode for central heating temperature range 20 85 C Po floor heating mode temperature range 20 60 C 5 Load temperature of DHW cylinder value on digital display 11 indi...

Page 17: ...c 13 Connecting of external devices NA RP Tzas Q Twej Twyj Ci ZM Pompa ZTD N L N L N LA LB Za NTC Sensor Thermostat PROG 0 6 12 18 24 0 c Ni Po Wt r Cz Pt So COM NO NC Auraton 2005 lub NO COM BK NC LA...

Page 18: ...t passing through the heating element A U Working voltage of the heating elements V EKCO L2NF 4 01184 wyk 001 3 37 1 40 9 5 6 6 2 230 EKCO L2NF 6 01186 wyk 003 3 24 8 28 6 8 0 9 3 EKCO L2N 4 01184 wyk...

Page 19: ...connection 400V 3N 12 24 kW wyk I Pic 15 Power board connection 12 24 kW 3N Power supply 400V 3N U V W N Ground NA RP Tzas Q Twej Twyj Ci ZM Pompa ZTD N L N L N LA LB Za H e 1 H e 2 H e 3 red blue L3...

Page 20: ...2 Power board connection 400V 3N 4 8 kW wyk II Pic 16 Power board connection 4 8 kW 3N Power supply 400V 3N U V W N Ground NA RP Tzas Q Twej Twyj Ci ZM Pompa ZTD N L N L N LA LB Za H e 1 H e 2 H e 3...

Page 21: ...8 kW wyk III ver 1 Pic 17 Power board connection 4 8 kW N ver 1 date of production before 17 11 2010 Power supply 230V N U N Ground NA RP Tzas Q Twej Twyj Ci ZM Pompa ZTD N L N L N LA LB Za H e 1 H e...

Page 22: ...Ground NA RP Tzas Q Twej Twyj Ci ZM Pompa ZTD N L N L N LA LB Za H e 1 H e 2 H e 3 red blue L3 G3 L2 G2 L1 G1 N V W The second version allows you to configure the installation for one or three phase p...

Page 23: ...BK U V W N Tzas NTC LA LB ZTD N F1 T1 Return temperature sensor MSK MSK board ZM power board Q flow sensor ZG heating box Kp front cover M1 circulating pump XP terminal strip LPE F1 WT 3 cut out T2 fl...

Page 24: ...WT 3 N PE Power supply 400v 3N U V W N Tzas NTC LA LB ZTD N T1 return temperature sensor MSK MSK board ZM power board Q flow sensor ZG heating box Kp front cover M1 circulating pump XP terminal strip...

Page 25: ...P L Zas N U V W WT 3 N PE U N Tzas NTC LA LB ZTD N Power supply 230V N BK RP NC NC T1 return temperature sensor MSK MSK board ZM power board Q flow sensor ZG heating box Kp front cover M1 circulating...

Page 26: ...M power board Q flow sensor ZG heating box Kp front cover M1 circulating pump XP terminal strip LPE F1 WT 3 cut out T2 flow temperature sensor Kd bottom cover BK boiler lock always closed RP room ther...

Page 27: ...pipe 16 01183 PCA ZM 60 02 Power board EKCO L2 1 17 01182 PSK P5 00 00 00 Control panel PSK P5 1 01338 Control panel PSK P5 EHC 1 18 01212 Flow sensor DN15 200 915101 EKCO T TM 1 19 01229 Flow sensor...

Page 28: ...Power board ver 2b connection 400V 3N 12 24 kW Power supply 230 400V U N Ground NA RP Tzas Q Twej Twyj Ci ZM Pompa ZTD N L N L N LA LB Za H e 1 H e 2 H e 3 red blue L3 G3 L2 G2 L1 G1 N V W Pic 23 Conn...

Page 29: ...ction 230V N 400V 3N 4 8 kW Power supply 230 400V U N Ground NA RP Tzas Q Twej Twyj Ci ZM Pompa ZTD N L N L N LA LB Za H e 1 H e 2 H e 3 red blue L3 G3 L2 G2 L1 G1 N V W Pic 24 Connection of power boa...

Reviews: