- Boiler protection:
Yes - if the temp of the inside sensor of the boiler drops below 5*C, the circulation
pump will turn on
No - protection turned off
•
Outside temp: the configuration parameters of the outside temperature sensor.
- Sensor Tos:
Yes - sensor on, all functions related to external temperature will be active,
No - sensor inactive - disables the function Emergency out. temp.. In the absence
or failure of the sensor, the error Tos is not displayed.
- Outside temp off: the value of the outside temperature after which the heating of
the CH circuit is switched off. The histeresis equals 2°C. For example, for a setting
of 15°C, the heating will be switched off if the outside temperature reaches 15°C,
the heating will be switched on if the outside temperature drops to 13°C. Parameter
available with active Tos sensor.
- Emergency out temp: the parameter used to calculate the heating curve in the event
of a failure of the outside temperature sensor
- Tos calibration: calibrating the value of the indicated outside temperature. Depending
on the character, the parameter is added or subtracted from the measured value.
Parameter available with active Tos sensor.
•
DHW CYLINDER:
- Control: selection of the three-way valve control pattern:
- A-DHW B-CH
- A-CH B-DHW
- DHW coil temperature: coil’s feed temperature
- Regulation: DHW cylinder temperature control:
Inside>performance according to the internal controller (built into the device),
the time programmer and the measured temperature in the cylinder. To work
in internal controller mode, Tcyl sensor is required.
Outside> according to external thermostat ( in OUTSIDE setting the following
modes are not available: DHW CYLINDER TEMPERATURE, DHW CYLINDER
PROGRAM, DISINFECTION and MANUAL DHW ).
- Cancel: turning off the DHW function.
•
Circulation: enabling or disabling the DHW circulation pump control and DHW system
circulation function.