24
•
Pressure sensor:
No - turning the control off
Yes - turning the control on
Pressure control should be switched off only when boiler works in an open CH
system.
•
Working mode:
Standard: boiler is the only device that controls CH system.
Source: the boiler acts only as a heat source and the heating system is controlled
by heating modules.
Buffer: the boiler controls the function of charging the buffer, buffer discharge is
controlled by the heating modules
•
PV options:
- Energy limit:
Yes - energy limit turned on
No - energy limit turned off
- Tr offset: the value by which the boiler can increase the room temperature at the
time of PV energy production (Entry FN short circuit). This feature is available
when cascading is disabled
[Configuration > Cascade: No]
, the boiler runs in
satndard mode [Configuration > Working mode: Standard] and FN entry set to PV
[Configuration > Entry FN: PV]
.
•
Cascade:
No - disabled operation in the cascading mode,
Yes - enabled operation in the cascading mode.
Cascading boiler connection is not available in buffer mode.
Exit any menu item by pressing „END” or by pressing and holding the navigation dial.
When not operated by the user, main function screen will appear after about 3 min.
If CMG.3 heating modules are connected to the boiler, additional options will be displayed
in the configuration menu. A detailed description can be found in the module manual.