a) When controlling this product by sending one control command.
This product can be controlled.
Please send control command in the following order.
1. Character (input line or action select command).
2. Delimiter.
3. Character (output line select command).
4. Return.
※
Set the front dip switch to Registration mode.
Please refer to "4-1 The setting of front dip switch."
(Ex.1) input : IN2, output : CAT5
ASCII character representation B , 1 return
HEX representation 42H 2CH 31H 0DH
(Ex.2) input : IN6, output : SUB
ASCII character representation F , 2 return
HEX representation 46H 2CH 32H 0DH
(Ex.3) Turning OFF of CAT5OUT.
ASCII character representation Q , 1 return
HEX representation 51H 2CH 31H 0DH
(Ex.4) Turning OFF of SUBOUT.
ASCII character representation Q , 2 return
HEX representation 51H 2CH 32H 0DH
(Ex.5) Turning ON of POWER CONT.
ASCII character representation J , 3 return
HEX representation 4AH 2CH 33H 0DH
(Ex.6) Turing OFF of DISPLAY POWER (switching to CAT5 OUT).
ASCII character representation I , 6 return
HEX representation 49H 2CH 36H 0DH
(Ex.7) Turing ON of OPTION B.
ASCII character representation L , 3 return
HEX representation 4CH 2CH 33H 0DH
※
This product sends, ACK (06H), as answer-back when operation of one control command
is executed.
This product sends, NAK (15H), as answer-back when operation of one control command
is not executed.
‑19‑