background image

Usage Cautions

Please be sure to read this manual prior to usage of product. After reading, keep it in 
a place near the equipment where it can be easily referred to.

Warning

If this symbol is ignored death or serious injury may

    occur.

Caution

If this symbol is ignored injury or property damage may

   occur.

● 

We are not responsible for damages to an image or sound transmitted by 

     our product caused by the products malfunction or any other outside factor.

 Shows caution 

  (including warning)

 Shows an action that should not be done.

 Shows an action that should be done.

Explanation of symbols 

General caution

Prohibited

Do not use in
a wet place

Do not attempt
to take apart

Do not touch

Do not touch
with wet hands

Do not expose 
to water

Keep hands clear

General indication

Unplug the power cord

Summary of Contents for KE811CT

Page 1: ...KE811CT w type CAT5 SWITCHER Ver 1 0E Instruction Manual Thank you for your purchase of this product Please be sure to read this manual completely prior to usage of this product ...

Page 2: ... of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference ...

Page 3: ... may occur We are not responsible for damages to an image or sound transmitted by our product caused by the products malfunction or any other outside factor Shows caution including warning Shows an action that should not be done Shows an action that should be done Explanation of symbols General caution Prohibited Do not use in a wet place Do not attempt to take apart Do not touch Do not touch with...

Page 4: ...s product except for the specified voltage and current AC100 240V May cause fire or electric shock Do not stick any foreign objects into the product May cause fire or electric shock Do not allow the product to get wet May cause fire or electric shock Do not touch the power cord during a thunder storm May cause electric shock Plug the product into an outlet that can be easily reached Unplug the pro...

Page 5: ...or turn it upside down Do not cover the ventilation holes or stick foreign objects into this product as it will cause damage Disconnect all cables before moving this product The cables can be damaged and fire or electric shock may occur if not disconnected Do not place a heavy object on this product Placing a heavy or oversized object on the product may cause injury as a result of it falling Disco...

Page 6: ...personal computer 5 3 Control and registration method 5 Serial interface 15 15 17 5 2 Connection of RS232C cable 16 4 1 The setting of front dip switch 12 2 2 Rear panel 5 4 3 Operation of buttons 14 17 5 3 1 Control method 21 5 3 2 Registration method 7 Specifications 23 6 Parallel interface 22 7 1 The specifications of this product 23 24 7 2 2 Connector for tally output 24 25 7 2 3 Connector for...

Page 7: ...OUT CAT5 OUT OFF 8 7 6 5 4 3 2 1 INPUT F OPTION E D B A C DISPLAY POWER CONT POWER KE811CT Instruction Manual Thank you for your purchase of this product Please be sure to read this manual completely prior to usage of product 1 About this product KE811CT w type 1 1 Product and accessories Please check that you have the accesories and items shown 1 Terminal 2 pin 2 Terminal 6 pin 2 AC adapter Power...

Page 8: ...ended transmission distance is 10m 32 8ft The maximum recommended transmission distance depends on the refresh rate and resolution The transmission distance when using our recommended cable is as follows Recommended cable OKTP E5 P AWG24x4P OKANO ELECTRIC WIRE CO LTD The features of this product are below mentioned Transmitting one line for twisted pair 2 distributed outputs and one line for monit...

Page 9: ...ton Command is transmitted to CAT5 OUT when DISPLAY POWER button is pressed after pressing CAT5 OUT button OPTION button When this button is pushed the signal photo MOS relay make contact is output from connectors for OPTION A F Output can be selected momentarily or alternately The equipments connected to CAT5 OUT and SUB OUT SERIAL 2 of rear panel can be controlled in command Please refer to 4 2 ...

Page 10: ...his connector is used to register commands into the product Please refer to 5 2 Connection of RS232C cable Front LED Yellow LED It does not light Green LED It lights when command mode is ON Orange LED It lights when SERIAL1 3 are transmitting or receiving Bottom dip switch Option setting is available etc Please refer to 4 2 The setting of bottom dip switch 4 ...

Page 11: ...ors are corresponding to INPUT 5 8 on front panel Please use a cable under 3m 9 84feet in length when connecting COMPONENT IN 4 RCA connector video input connector for SUB OUT For component video input connector These connectors are corresponding to INPUT 4 on front panel Please use a cable under 3m 9 84feet in length when connecting RGB_SUB_OUT 15pin HD female video output connector for SUB OUT T...

Page 12: ... can be transmitted to SUB Please use a cable under 3m 9 84feet in length when connecting SERIAL 1 DB9 connector for serial communication Serial communication is available Through this connector the product can be controlled Straight cable is needed when this product is connected Personal Computer Please refer to 5 2 Connection of RS232C cable SERIAL 2 DB9 connector for serial communication Comman...

Page 13: ... this case run the twisted pair cable away from the power supply line If this product is connected to an AC power supply with noise the image may flicker In this case use an AC wall socket type noise filter Use the cable mounting kits when undesirable force will be applied to the twisted pair connectors of this product Please refer to 3 3 Cable mounting kit Rack mounting kit Warnings Do not connec...

Page 14: ...CAT6 cable is used to connect this product and twisted pair receiver This product and receiver are connected straight through as shown in the diagram below Please keep the combination of the pair lines as follows If the combination of a pair line is incorrectly installed there is a possibility that the quality of the image may deteriorate 8 ...

Page 15: ...ure the rack mounting kits to this product and the rack using the supplied screws Loads other than this product must not weight on the rack mounting kits The power cord and AC adapter must be used in the rating 9 RGB IN8 SERIAL 3 AUDIO IN8 1 4 SUB OUT CAT5 OUT OFF 8 7 6 5 4 3 2 1 INPUT F OPTION E D B A C DISPLAY POWER CONT POWER KE811CT 2 1 AUDIO IN 1 COMPOSITE IN 2 3 3 COMPOSITE SUB OUT RGB IN 6 ...

Page 16: ...ponent for SUB OUT Connector 1 COMPOSITE IN 2 3 COMPOSITE SUB OUT COMPONENT IN RGB SUB OUT a Composite video b Component video 21 22 2 1 AUDIO IN 1 COMPOSITE IN 2 3 3 COMPOSITE SUB OUT RGB IN 6 5 4 5 6 7 7 AUDIO SUB OUT COMPONENT IN SERIAL 1 RGB SUB OUT SERIAL 2 CAT5 OUT2 CAT5 OUT1 A B C D E F OPTION OUT PARALLEL REMOTE POWER CONT DC16V IN FG 4 25 26 24 23 RGB IN8 SERIAL 3 AUDIO IN8 1 4 SUB OUT CA...

Page 17: ...ease refer to the manual of twisted pair receiver Ⅳ Connect between this product and twisted pair receiver by using CAT5e or CAT6 cable Please refer to 3 2 Preparation of cable Ⅴ Fix the CAT5e or CAT6 cable by cable mounting kit Please refer to 3 3 Cable mounting kit rack mounting kit Warnings Turn on the each equipment according to below mentioned First connect AC adapter to this product Next tur...

Page 18: ...ation mode Regardless of the setting of No 2 4 OFF Standard mode 2 no working 3 ON POWER CONT becomes ON when AC adapter is connected to outlet OFF POWER CONT becomes ON when POWER CONT is pressed 4 no working 12 All switches of front dip switch are set at OFF as initial setting ...

Page 19: ...utton momentary OFF OPTION C button alternate 4 ON OPTION D button momentary OFF OPTION D button alternate 5 ON OPTION E button momentary OFF OPTION E button alternate 6 ON OPTION F button momentary OFF OPTION F button alternate 7 ON POWER CONT button DIPLAY POWER button synchronization mode OFF un synchronization 8 no working All switches of bottom dip switch are set at OFF as initial setting 13 ...

Page 20: ... curtain or screen etc with relay of rear panel The setting alternate momentary is available with bottom dip switch Please refer to 4 2 The setting of bottom dip switch The command can be transmitted to both of CAT5 and SUB SERIAL 2 If the command would not be transmitted to CAT5 do not register any command in CAT5 If the command would not be transmitted to both of CAT5 and SUB SERIAL 2 do not reg...

Page 21: ...e 5 1 The setting of personal computer Set the personal computer as follows when this product is controlled Baud rate 9600bps Data bits 8 Stop bits 1 Parity bits none Handshaking none Communication method full duplex 15 ...

Page 22: ...E ready Pin7 Request to send RTS Pin8 Clear to send CTS Pin9 Non connect NC Serial 1 3 Pin Out Diagram Pin1 Non connect NC Pin2 Received Data RD Pin3 Transmitted Data TD Pin4 DTE Pin5 GND Pin6 It connects with Pin4 Pin7 It connects with Pin8 Pin8 It connects with Pin7 Pin9 Non connect NC Serial 2 Pin Out Diagram Pin Number 1 2 3 4 5 6 7 8 9 16 ...

Page 23: ... select output Remark 2 This character is used when POWER CONT OPTION are ON OFF Remark 3 This character is used to select output CAT5 when DISPLAY POWER is ON Remark 4 This character is used to select output CAT5 when DISPLAY POWER is OFF Remark 5 This character is used to select output SUB when DISPLAY POWER is ON Remark 6 This character is used to select output SUB when DISPLAY POWER is OFF Rem...

Page 24: ...istration command only Memory size of control command is 32bytes 8 commands The data length that can be sent at a time is 32bytes If more than 32bytes data is transmitted please send the data after answer back is returned If control command is transmitted before answer back is returned it may not be executed During serial communication the operation of button may not be valid ...

Page 25: ... 32H 0DH Ex 3 Turning OFF of CAT5OUT ASCII character representation Q 1 return HEX representation 51H 2CH 31H 0DH Ex 4 Turning OFF of SUBOUT ASCII character representation Q 2 return HEX representation 51H 2CH 32H 0DH Ex 5 Turning ON of POWER CONT ASCII character representation J 3 return HEX representation 4AH 2CH 33H 0DH Ex 6 Turing OFF of DISPLAY POWER switching to CAT5 OUT ASCII character repr...

Page 26: ...miter n 3 Character selecting IN n 2 Delimiter n 1 Character selecting OUT n Return n 32 Set the front dip switch Please refer to 4 1 The setting of front dip switch Ex 1 Turning ON of POWER CONT turning ON of OPTION A turning ON of OPTION B ASCII Character representation J 3 K 3 L 3 return HEX representation 4AH 33H 4BH 33H 4CH 33H 2CH 3BH 2CH 3BH 2CH 0DH This product sends ACK 06H as answer back...

Page 27: ...n HEX representation 57H 0DH Receiving ASCII Character representation C D return HEX representation 43H 3BH 44H 0DH Ex 2 When OFF is selected for CAT5 OUT IN4 is selected for SUB OUT Sending ASCII Character representation W return HEX representation 57H 0DH Receiving ASCII Character representation Q D return HEX representation 51H 3BH 44H 0DH Do not send together with control command consecutively...

Page 28: ... 22 GND 23 GND 24 GND 25 GND 26 27 28 29 30 31 POWER CONT IN 32 DISPLAY POWER IN 33 IN 34 IN 35 IN 36 IN 37 IN 38 IN OPTION A OPTION B OPTION C OPTION E OPTION F OPTION D IN1 Composite1 IN2 Composite2 IN3 Composite3 IN4 Component IN5 RGB1 IN6 RGB2 IN7 RGB3 IN8 RGB4 CAT5 IN IN IN IN IN IN IN IN 39 40 41 42 43 44 45 46 47 48 49 50 SUB OFF MUTE IN IN IN 5V 5V 5V 5V 5V 6 Parallel interface This produc...

Page 29: ...tor 50 pin 6pin Terminal connector for Contact output 2 2pin Terminal connector for Power control Temperature 0 40 humidity 20 80 no condensation Approximately 10W Input AC100V 240V 50 60Hz 1 0A Output DC16V 2 5A W422 D250 H44 mm Approximately 3kg KE811CT w type Model name Control and remote 7 Specifications 7 1 The Specifications of this product 23 Input signal Output signal Input connector Outpu...

Page 30: ... output relay no polarity relay no polarity Relay type photo MOS relay make contact Rating maximum 50mA less than AC DC 24V Internal circuit is as follows Caution Do not supply more than AC DC 24V When option button is set as momentary output output pulse width is about 200msec fuse varistor A B C D E F OPTION OUT POWER CONT Relay specification ...

Page 31: ...or for tally output Connector pin No 1 19 for output Connector pin No 21 25 for GND Connector pin No 26 30 DC5V Output type open collector Pullup internal 10KΩ 5V connection Rating maximum 20mA DC5V Caution Do not exceed the rating Please put register R to protect overcurrent as follows 1 2 3 4 25 26 50 PARALLEL REMOTE Caution Please use within 20mA when DC5V is used R ...

Page 32: ...ct Please use non voltage contact by momentary switch non lock or open collector of transistor when parallel input is executed Parallel remote connector GND 25 32 49 Please input as following timing IN t t 500ms 21 GND 31 t1 t1 20ms 26 1 2 3 4 25 26 50 PARALLEL REMOTE Parallel input may not operate when this product is controlled in serial communication ...

Page 33: ... or CAT6 cable connected to OUT1 or OUT2 of this product Is the cable properly connected to the video input connector of this product Are cables properly connected to IN connectors Is the length of the cable within the recommended maximum transmission distance Did you adjust a LEVEL PEAKING of a twisted pair receiver 3 3 Cable mounting kit and Rack mounting kit 3 3 Cable mounting kit and Rack moun...

Page 34: ...ted to the AUDIO OUT connector of the twisted pair receiver Is the length of the cable within the recommended transmission distance 1 2 General Information Serial communication can t be performed Command registration can t be performed Is the cable properly connected Does the kind of cable suit straight or cross Does a setup of a front dip switch suit Does the command suit 5 2 Connection of RS232C...

Page 35: ... Design and specifications are subject to change without notice 2006 4 14 B ...