(5)
Server Mode Address Mapping Table (SJ-Ether)
Memory type
Score
(decimal
number)
PLC range
(octal number)
MODBUS scope
(decimal
number)
Corresponding function code
(○:Corresponding,
△
: Partially supported,-: Not
supported)
01
02
03
04
05
06
07
08
15
16
Input (I)
1024
I0
~
1777
2048
~
3071
-
○
-
-
-
-
-
-
-
-
Special relay (SP)
512
SP0
~
777
3072
~
3583
-
○
-
-
-
-
-
-
-
-
Output (Q)
1024
Q0
~
1777
2048
~
3071
○
-
-
-
○
-
△
-
○
-
Internal relay (M)
2048
M0
~
3777
3072
~
5119
○
-
-
-
○
-
-
-
○
-
Timer contact (T)
256
T0
~
377
6144
~
6399
○
-
-
-
○
-
-
-
○
-
Counter contact (C)
256
C0
~
377
6400
~
6655
○
-
-
-
○
-
-
-
○
-
Stage state bit (S)
1024
S0
~
1777
5120
~
6143
○
-
-
-
○
-
-
-
○
-
Global input (GI)
2048
GI0
~
3777
0
~
2047
-
○
-
-
-
-
-
-
-
-
Global Output (GQ)
2048
GQ0
~
3777
0
~
2047
○
-
-
-
○
-
-
-
○
-
Timer elapsed value (R)
256
R0
~
377
0
~
255
-
-
○
○
-
○
-
-
-
○
Counter elapsed value
(R)
256
R1000
~
1377
512
~
767
-
-
○
○
-
○
-
-
-
○
Data register (R)
256
R400
~
777
256
~
511
-
-
○
○
-
○
-
-
-
○
3072
R1400
~
7377
768
~
3839
8192
R10000
~
27777
4096
~
12287
Special register (R)
256
R7400
~
7777
3840
~
4095
-
-
○
○
-
○
-
-
-
○
When the communication partner (slave device) is SJ-Ether in function code 07, one byte data of Q0-Q7 can be read.
If the other party is not SJ-Ether, it complies with the specifications of the slave device.
(6)
Client mode address mapping table (MRX/MWX counterpart device: SJ-Ether)
If the other device is not SJ Ether, the MODBUS/KOYO address translation utility (modbus_conversion Rev*). **Download.xls from the
following Technical Support website. www.koyoele.co.jp
Memory type
Score
(decimal
number)
PLC range
(octal number)
MODBUS scope
(decimal
number)
Corresponding function code
(○:Corresponding,
△
: Partially supported,-: Not
supported)
01
02
03
04
05
06
07
08
15
16
Input (I)
1024
I0
~
1777
2048
~
3071
-
○
-
-
-
-
-
-
-
-
Special relay (SP)
512
SP0
~
777
3072
~
3583
-
○
-
-
-
-
-
-
-
-
Output (Q)
1024
Q0
~
1777
2048
~
3071
○
-
-
-
○
-
△
-
○
-
Internal relay (M)
2048
M0
~
3777
3072
~
5119
○
-
-
-
○
-
-
-
○
-
Timer contact (T)
256
T0
~
377
6144
~
6399
○
-
-
-
○
-
-
-
○
-
Counter contact (C)
256
C0
~
377
6400
~
6655
○
-
-
-
○
-
-
-
○
-
Stage state bit (S)
1024
S0
~
1777
5120
~
6143
○
-
-
-
○
-
-
-
○
-
Global input (GI)
2048
GI0
~
3777
0
~
2047
-
○
-
-
-
-
-
-
-
-
Global Output (GQ)
2048
GQ0
~
3777
0
~
2047
○
-
-
-
○
-
-
-
○
-
Timer elapsed value
(R)
256
R0
~
377
0
~
255
-
-
○
○
-
○
-
-
-
○
Counter elapsed value
(R)
256
R1000
~
1377
512
~
767
-
-
○
○
-
○
-
-
-
○
Data register (R)
256
R400
~
777
256
~
511
-
-
○
○
-
○
-
-
-
○
3072
R1400
~
7377
768
~
3839
8192
R10000
~
27777
4096
~
12287
Special register (R)
256
R7400
~
7777
3840
~
4095
-
-
○
○
-
○
-
-
-
○
When the communication partner (slave device) is SJ-Ether in function code 07, one byte data of Q0-Q7 can be read.
If the other party is not SJ-Ether, it complies with the specifications of the slave device.
Summary of Contents for Kostac SJ-Ether Series
Page 1: ...English version of the KOSTAC SJ Ether series user s manual SJ ETHER USER M...
Page 12: ......
Page 13: ...1...
Page 14: ......
Page 88: ......
Page 89: ......
Page 113: ...3 24 Note Refer to 6 3 3 Module Assembly for connections and locks between modules...
Page 153: ......
Page 156: ...flashing OFF Not sent H W RX Green flashing Receiving H W OFF Not received H W...
Page 161: ...4 8...
Page 221: ......
Page 310: ...Chapter 7 Maintenance...
Page 311: ......