6-18
(3)
Connection of external power supply
The following modules require an external power supply. Refer to Chapter 3 and connect the necessary external power
supply.
SJ-11DD1E-D/SJ-12DD1E-D/SJ-11DD1EP-D/SJ-12DD1EP-D/J-08TD1/J-16TD1/J-16CDD1/C0-04AD-1/C0-04AD-2/
C0-04DA-1/C0-04DA-2/C0-4AD2DA-1/C0-4AD2DA-2
(4)
I/O wiring
The SJ Ether series uses a removable European-type terminal block. During maintenance, it is possible to attach or
disconnect the wiring without rewiring one point at a time. Connect the wiring according to the specifications of the
terminal block shown in the table below.
Item
Specification
Pitch
3.5
㎜
Applicable wire AWG size
16
~
28 AWG
Strip length of the wire
7
㎜
Screw size
M2.0
Tightening torque
0.22
~
0.25 Nm
Note: Use a wiring route that is separate from the input and output wires.
・
Install the shielded wire on the PLC side using a straight line or a bulk shielded cable when it is impossible to separate
from the main circuit or power-driven vessel
・
Be sure to install the piping securely when piping is connected.
・
Separate the I/O lines below the DC 24 V from the AC 100 V and AC 200 V lines.
・
Use all shielded cables for wiring of microvoltages/currents, high-speed inputs, and high-speed pulse signals such as
analog modules
Install the shield on the PLC side.
DC input
AC output
Plumbing
Grounding
Duct
Summary of Contents for Kostac SJ-Ether Series
Page 1: ...English version of the KOSTAC SJ Ether series user s manual SJ ETHER USER M...
Page 12: ......
Page 13: ...1...
Page 14: ......
Page 88: ......
Page 89: ......
Page 113: ...3 24 Note Refer to 6 3 3 Module Assembly for connections and locks between modules...
Page 153: ......
Page 156: ...flashing OFF Not sent H W RX Green flashing Receiving H W OFF Not received H W...
Page 161: ...4 8...
Page 221: ......
Page 310: ...Chapter 7 Maintenance...
Page 311: ......