Chapter 2 Systems specification
2-16
Number
N a m e
C o n t e n t s
Detailed
SP070
Sign flag
0:When the calculation result is
positive
1:When the calculation result is
negative
Displays the status of the most significant
bit (bit 31) of the ACC.
SP071
Indirect specification error
0:When indirect setting is normal
1:When indirect setting is abnormal
ON when the register number of the
indirectly
specified
destination
is
abnormal.
SP072
Non-numeric flag
0:Floating-point value is valid
1:Floating-point value is invalid
ON when the floating-point value of the
accumulator is invalid
Number
N a m e
C o n t e n t s
Detailed
SP073
Overflow flag
0:Other than overflow
1:Time of overflow
ON when overflow occurs as a result of
calculation as signed data.
SP074
Underflow flag
0:Other than underflow
1:During underflow
ON when overflow occurs as a result of
calculation
SP075
Data error flag
0:Other than data errors
1:Time of data error
ON when BCD operation data is not
BCD
SP076
Read zero flag
0:Read value other than zero
1:When the read value is zero
ON when data loaded by load command
is 0
SP077
Contract
SP100
I0000 Input state
0:Terminal OFF
1:Terminal ON
Effective only when input is set to
Pulse Scatch
SP101
I0001 Input state
0:Terminal OFF
1:Terminal ON
SP102
I0002 Input state
0:Terminal OFF
1:Terminal ON
SP103
I0003 Input state
0:Terminal OFF
1:Terminal ON
SP104
I0004 Input state
0:Terminal OFF
1:Terminal ON
SP105
I0005 Input state
0:Terminal OFF
1:Terminal ON
SP106
I0006 Input state
0:Terminal OFF
1:Terminal ON
SP107
I0007 Input state
0:Terminal OFF
1:Terminal ON
SP110
-
SP111
Contract
SP112
Programmer
communication
port
Communication flag
0:Other than during forwarding
1:During transmission
Forwarding condition when sending on
the programmer communication port
(Port1)
SP113
Programmer
communication
port
Communication error flag
0:No forwarding error
1:Forwarding error
Master instruction on programmer
communication port (Port1)
ON when communication error occurs
SP114
-
SP115
Contract
Summary of Contents for Kostac SJ-Ether Series
Page 1: ...English version of the KOSTAC SJ Ether series user s manual SJ ETHER USER M...
Page 12: ......
Page 13: ...1...
Page 14: ......
Page 88: ......
Page 89: ......
Page 113: ...3 24 Note Refer to 6 3 3 Module Assembly for connections and locks between modules...
Page 153: ......
Page 156: ...flashing OFF Not sent H W RX Green flashing Receiving H W OFF Not received H W...
Page 161: ...4 8...
Page 221: ......
Page 310: ...Chapter 7 Maintenance...
Page 311: ......