Chapter 2 Systems specification
2-25
Number
N a m e
C o n t e n t s
Initial value
R7660-R7663
General
purpose
communication port 3
IP address
Example 192.168.0.10 (stored on BCD)
R7660=192 R7661=168 R7662=0 R7663=10
192.168.0.10
R7664-R7667
General
purpose
communication port 3
Subnet Mask
255.255.0.0 (stored on BCD)
R7664=255 R7665=255 R7666=2555 R7667=0
255.255.0.0
R7670-R7673
General
purpose
communication port 3
Default Gateway
192.168.0.1 (stored on BCD)
R7670=192 R7671=168 R7672=0 R7673=1
0.0.0.0
R7674-R7676
General
purpose
communication port 3
MAC address
MAC address (stored by HEX): Example: 00 D0 7C
XX YY ZZ
R7674=D000 R7675=XX7C R7676=ZZYY
MAC address
00D07CXXYYZ
R7677
Contract
0
R7700
General
purpose
communication port 3
Received data length
Size of received data in MODBUS TCP
0
R7701
General
purpose
communication port 3
MODBUS TCP server no-communication time (sec)
None
R7702
EtherNet/IP status
EtherNet/IP
Extended
Device Status
Status information specified by the EtherNet/IP
protocol. The status information of the extended
device is stored. Each bit is assigned.
0
R7703
EtherNet/IP error codes
Contains the most recent error code specified by the
EtherNet/IP protocol.
0
R7704
EtherNet/IP Lost Counter
Counts the number of lost packets detected.
Sequence counter information is added to the Implicit
message from the originator, and the value is
incremented for each transmission. Check that the
sequence counter information is received in sequence.
If a skip occurs, the loss occurrence counter is inked.
This register can be deleted by the user program.
Note that the specifications of the sequence counter
differ between Omron and Toyopec.
This data can be cleared from the ladder program or
peripheral tools
0
R7705
EtherNet/IP disconnection
counters
Counts the number of times the EtherNet/IP network is
disconnected.
Disconnenction is detected when the normal network
state (establishment of Implicit communication) is
disconnected.
This register can be deleted by the user program.
This data can be cleared from the ladder program or
peripheral tools.
0
R7706
CC-Link IEF Basic
Disconnection counter
Counts the number of times the slave station is
disconnected.
None
R7707
CC-Link IEF Basic
Queue counter
Counts the number of resolutions of slave stations.
When the slave station is disconnected, the number of
dissociation columns is also counted.
None
R7710-R7717
Prohibition of use
0
R7720
Timer setting value start
register number
S-10D: Timer setting register top number
None
Summary of Contents for Kostac SJ-Ether Series
Page 1: ...English version of the KOSTAC SJ Ether series user s manual SJ ETHER USER M...
Page 12: ......
Page 13: ...1...
Page 14: ......
Page 88: ......
Page 89: ......
Page 113: ...3 24 Note Refer to 6 3 3 Module Assembly for connections and locks between modules...
Page 153: ......
Page 156: ...flashing OFF Not sent H W RX Green flashing Receiving H W OFF Not received H W...
Page 161: ...4 8...
Page 221: ......
Page 310: ...Chapter 7 Maintenance...
Page 311: ......