Chapter 2 Systems specification
2-27
Number
N a m e
C o n t e n t s
Initial value
R7737
CC-Link IEF Basic
Master station
Calendar (year)
The information is updated only while you are
participating in the network.
~
00 99[BCD]
None
R7740
Auto reset setting
Setting up the communication auto reset timer of the
communication port
Upper (15-8 bit): Programmer Communication Port
(Port1)
Lower layer (7-0 bit): General-purpose serial
communication port (Port2)
Setting range 30~60](BCD)
3030
R7741-R7746
Contract
0000
R7747
10 ms counter data
10 ms (1/100 sec) Counter value is stored irrespective
of CPU operation mode.
None
R7750
Contract
0000
R7751
External diagnostic error
code
The external diagnostic command stores the
diagnostic code: label when the FALT is executed.
0000
R7752
I/O array error
This field is set to the current model code for the array
error module.
0000
R7753
I/O array error
Stores the old model code for the array error module.
0000
R7754
I/O array error
Stores the base/slot number of the array error module.
0000
R7755
Fatal anomaly code
The error code is stored when a fatal error occurs.
0000
R7756
Severe error code
Stores the error code when a serious error occurs.
0000
R7757
Minor abnormality code
Stores the error code when a minor error occurs.
0000
R7760
Module error
Base number/slot number: unsupported
0000
R7761
Module error
Fixed to 0: Not supported
0000
R7762
Module error
Code: Not supported
0000
R7763
Syntax error
Program Address with Syntax Error
0000
R7764
Syntax error
Grammatical error code
0000
R7765
Scan count
Stores the number of scans since the start of RUN.
[HEX]
0000
R7766
Calendar (seconds)
~
0 59[BCD]
None
R7767
Calendar (minutes)
~
0 59[BCD]
None
R7770
Calendar (Hour)
0 to 23 (24h notation) [BCD]
None
R7771
Calendar (day of the
week)
0:Sun, 1: Mon, 2: Tue, 3: Wed, 4: Thu, 5: Fri, 6: Sat
None
R7772
Calendar (days)
~
1 31[BCD]
None
R7773
Calendar (month)
~
1 12[BCD]
None
R7774
Calendar (year)
~
00 99[BCD]
None
R7775
Scan time
The current scan time is stored. [ms]
None
R7776
Shortest scan time
Stores the shortest scan time after the start of RUN.
[ms]
None
R7777
Longest scan time
Stores the longest scan time after the start of RUN.
[ms]
None
Summary of Contents for Kostac SJ-Ether Series
Page 1: ...English version of the KOSTAC SJ Ether series user s manual SJ ETHER USER M...
Page 12: ......
Page 13: ...1...
Page 14: ......
Page 88: ......
Page 89: ......
Page 113: ...3 24 Note Refer to 6 3 3 Module Assembly for connections and locks between modules...
Page 153: ......
Page 156: ...flashing OFF Not sent H W RX Green flashing Receiving H W OFF Not received H W...
Page 161: ...4 8...
Page 221: ......
Page 310: ...Chapter 7 Maintenance...
Page 311: ......