Chapter 2 Systems specification
2-48
Note: *1:2 word register, so it is recommended to specify an even number.
Also, the last register in the register range cannot be specified.
*2:Special relay area cannot be specified.
Classification
Order
Num
ber
of
word
s
Operand
BCD
Multiplier
Four digits
MUL
1
R Register total range *1
P Entire range of indirect registers
8 digits
MULD
2
R Register total range *1 *2
P Entire range of indirect registers
Arbitrary bit length
~
(1 16)
MULF
2
1st word: GI, GQ, I, Q, M, S, T, C, SP
2nd word: K 1-16
Stacked
SMUL
1
No operand
Four-digit constant
MULS
1
~
K 0 9999
BCD
Divide
Four digits
DIV
1
R Register total range *1
P Entire range of indirect registers
8 digits
DIVD
2
R Register total range *1 *2
P Entire range of indirect registers
Arbitrary bit length
~
(1 16)
DIVF
2
1st word: GI, GQ, I, Q, M, S, T, C, SP
2nd word: K 1-16
Stacked
SDIV
1
No operand
Four-digit constant
DIVS
1
~
K 1 9999
Note: *1:2 word register, so it is recommended to specify an even number.
Also, the last register in the register range cannot be specified.
*2:Special relay area cannot be specified.
2-12-6
ASCII command
Classification
Order
Num
ber
of
word
s
Operand
ASCII
Order
Text transfer
3
(ASCII Characters)
ASCII input
AIN
7
R
ASCII search
AFIND
7
R
Extracting ASCII data
AEX
5
R
ASCII → HEX-coding
CMPV
4
R
ASCII byte swaps
SWAPB
3
R
Data Transfer from ASCII to Function
Memory
VPRINT
4
Text data
Data Transfer from Function Memory to
ASCII
PRINTV
6
R
Clearing ASCII buffers
ACRB
1
R
Summary of Contents for Kostac SJ-Ether Series
Page 1: ...English version of the KOSTAC SJ Ether series user s manual SJ ETHER USER M...
Page 12: ......
Page 13: ...1...
Page 14: ......
Page 88: ......
Page 89: ......
Page 113: ...3 24 Note Refer to 6 3 3 Module Assembly for connections and locks between modules...
Page 153: ......
Page 156: ...flashing OFF Not sent H W RX Green flashing Receiving H W OFF Not received H W...
Page 161: ...4 8...
Page 221: ......
Page 310: ...Chapter 7 Maintenance...
Page 311: ......