MAINTENANCE REQUIREMENTS
1.
The appliance must be inspected at least
once a year by a professional service person.
NOTE: INSTALLATION AND REPAIR SHOULD BE
DONE ONLY BY A QUALIFIED SERVICE PERSON.
THE APPLIANCE SHOULD BE INSPECTED BEFORE
USE AND AT LEAST ANNUALLY BY A QUALIFIED
SERVICE PERSON. MORE FREQUENT CLEANING
MAY BE REQUIRED DUE TO EXCESSIVE LINT
FROM CARPETING, BEDDING MATERIALS, ETC. IT
IS IMPERATIVE THAT CONTROL COMPARTMENTS,
BURNERS AND CIRCULATION AIR PASSAGEWAYS
OF THE APPLIANCE BE KEPT CLEAN.
2.
The compartment below the firebox (behind the
lower grill) must be cleaned at least once a year,
more frequent cleaning may be required due to
excessive lint from carpeting, bedding materials,
or other fibrous materials. It is imperative that the
burner be cleaned once a year.
FAN
The fan should be disconnected from electrical current,
and cleaned (vacuumed) several times a year. The
bearings are sealed and require no oiling.
VENT SYSTEM
Annual examination of the venting system by a
qualified agency is required.
1.
Remove the glass on the front of the unit.
2.
For easier access, remove the logs.
3.
Cover the millivolt board system.
4.
Loosen the nuts securing the baffle at the back
of the firebox and remove the baffle.
5.
Examine proper sealing of the vent system.
6.
Replace the baffle and secure the nuts. Do not
over-tighten the nuts!
7.
Replace the logs, glass and upper grill.
IMPORTANT: ANY SAFETY SCREEN OR GUARD
REMOVED FOR SERVICING MUST BE REPLACED
PRIOR TO OPERATING THE APPLIANCE.
CAUTION: LABEL ALL WIRES PRIOR TO DISCON-
NECTION WHEN SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND DANGER-
OUS OPERATION. VERIFY PROPER OPERATION
AFTER SERVICING.
CAUTION: KEEP THE APPLIANCE AREA CLEAR OF
COMBUSTIBLE MATERIALS, SUCH AS GASOLINE
AND OTHER FLAMMABLE VAPORS AND LIQUIDS
.
MILLIVOLT BOARD SYSTEM
1. Annual cleaning of the burner is required. The
burner cover may be removed for easier access.
2. Remove the logs.
3. Loosen and remove the 2 nuts securing the
burner cover. Remove the burner/cover assem-
bly, sliding it off the burner orifice.
4. Visually check for blocked port holes, especially
near the pilot. Blocked port holes will cause de-
layed ignition. Replace components by following
the instructions included with the manual.
5. Visually check the pilot light and burner when
they are burning. See Figures below. The flames
should be steady, not lifting or floating.
Burner Orifice
Pilot Assembly
GLASS CLEANING & REPLACEMENT
∙
Clean glass only when cool and only with non-abrasive
cleansers.
∙
Do not operate this fireplace with the glass/frame
assembly remove, cracked or broken.
∙
∙
Replacement of the glass & gasket assembly,
Part #700-08T - must only be performed by a licensed
or qualified service person. DO NOT SUBSTITUTE
MATERIALS.
∙
Do not strike or slam glass door assembly.
CAUTION: KEEP THE APPLIANCE AREA CLEAR OF
COMBUSTIBLE MATERIALS, SUCH AS GASOLINE AND
OTHER FLAMMABLE VAPORS AND LIQUIDS
.
Page 27