#LXL-22-L
R.1 4 . 2 0 . 2022
39
HUSSONG MFG. CO., INC.
KOZY HEAT FIREPLACES
SECTION 10
ADJUSTMENT
Burner Flame Adjustments
Adjustable venturi lever
Wing nut securing
adjustable venturi
lever
FIGURE 10.2
Adjustable Venturi Lever location
10.2
Burner Flame Adjustments
WARNING: To avoid property damage or personal injury, allow the
fireplace ample time to cool before making any adjustments.
Burner flame appearance and characteristics are affected by
altitude, fuel quality, venting configuration, and other factors. After
installation, this appliance may need additional adjustments to
achieve optimum flame appearance and visual aesthetics.
10.2.1
Burner Venturi
WARNING: VENTURI ADJUSTMENT MUST BE DONE BY A QUALIFIED
SERVICE TECHNICIAN.
When this appliance is first lit, the burner flames will appear blue.
During the first 15 minutes of operation, flame appearance will
gradually turn to the desired yellow appearance. If the flames remain
blue, or become dark orange with evidence of sooting (black tips),
adjustment of the air shutter opening may be necessary.
Regardless of venturi orientation, closing the air shutter will achieve a
desired yellow flame, but may produce soot on the glass. Opening the
air shutter will cause a short, blue flame that may lift off the burner.
Slight adjustments to the venturi opening will create dramatic results.
Adjust at slight increments until desired look is achieved.
NOTE: If soot is present on the logs, check log placement (section
7.3
on page 29) before adjustment.
T a b le
1 0 .3 , F a c to ry S e t V e n tu ri O p e n in g s
Fuel
Venturi Opening
Natural Gas
1/4” (6.35mm) OPEN
Propane
5/8” (15.88mm) OPEN
1.
Open the door of the control enclosure located below the
firebox of the gas stove.
2.
Locate the adjustable venturi lever (
FIGURE 10.2
)
3.
Loosen the wing nut securing the lever and adjust the burner
venturi (
FIGURE 10.3
) as necessary. See flame adjustment
guidelines in
FIGURE 10.4
. Re-tighten wing nut when finished.
Moving the adjustable venturi lever to the right opens the air
shutter opening and increases air.
Moving the adjustable venturi lever to the left closes the air
shutter opening and decreases air.
4.
Close the door of the control enclosure.
FIGURE 10.4
Flame Appearance and Characteristics
Burner venturi
FIGURE 10.3
Burner Venturi