10.2.2
Vent Restriction (after installation)
10.2.2.1
Baffle Restrictor Adjustment
SECTION 10
ADJUSTMENT
Burner Flame Adjustments
WARNING: To avoid property damage or personal injury, allow the
fireplace ample time to cool before making any adjustments.
WARNING: Improper vent installation may cause the burner flames
to lift or “ghost.” Perform a visual check on flame appearance after
restriction adjustment to ensure proper performance.
Vertical terminations may display an active, compact flame. If
this appearance is not desirable, a restrictor plate may need to be
installed or modified after vent termination installation. Access to the
vent exit for restriction can be reached through the fireplace baffle.
Refer to
TABLE 10.4
and
FIGURE 10.5
for flame appearance
adjustments. Allow the fireplace to burn for 15 minutes before
making any adjustments.
1.
Remove the safety barrier and glass frame assembly to access
the baffle restrictor.
2.
Remove and save (1) screw to adjust the baffle restrictor to
achieve desired flame appearance. Position 1 is the least
restriction, and position 5 is the most restriction
3.
Secure baffle restrictor with (1) screw previously removed.
4.
Reinstall the glass frame assembly and safety barrier.
T a b le
1 0 .4 , R e s tric to r P la te A d ju s tm e n t G u id e lin e s
Flame Appearance
Draft Problem
Solution
Short, flickering
Excessive draft
Not enough restriction
Add restrictor plate
Close baffle restrictor
Lifting or ghosting*
Insufficient draft
Remove inner ring(s)
on restrictor plate, or;
remove restrictor plate
Open baffle restrictor
*If flames continue to lift or ghost after opening the restrictor plate
and verifying correct vent installation, shut off the gas supply and call a
qualified service technician.
FIGURE 10.5
Flame Appearance and
Characteristics for Restricting Vent
FIGURE 10.6
Baffle Restrictor Adjustments