44
#LXL-22-L
R.1 4 . 2 0 . 2022
HUSSONG MFG. CO., INC.
KOZY HEAT FIREPLACES
SECTION 11
TROUBLESHOOTING
Issue
Cause
Solution
Flame burns blue and lifts
off burner
Improper venturi setting
The venturi air shutter may need to be closed slightly to allow less air
into the gas mix. Refer to section
10.2.1, BURNER VENTURI
on page
39.
Incorrect vent cap installation
Adjust if necessary.
Blockage or leakage of the vent
system
Check the vent pipes for leaks, and the vent cap for debris. Repair the
vent pipes or remove debris from vent cap, if necessary.
No reaction to command
Battery back batteries or remote
control batteries low
Replace batteries.
No communication between
remote control and control
module
Reprogram remote control to Komfort 8K1 module. Refer to section
9.2,
INITIALIZE THE KOMFORT 8K1 CONTROL SYSTEM
on page 33.
A maximum number of failed
ignitions or flame restorations has
been reached
Reset Komfort 8K1 control module. Refer to section
9.6, KOMFORT 8K1
CONTROL SYSTEM IGNITION SEQUENCE
on page 33.