FINALIZING THE INSTALLATION
FLAME APPEARANCE:
Flame appearance is affected by several factors including altitude, venting configuration and fuel quality. Although the venturi settings
have been factory set, adjustments may be necessary for optimal performance and visual aesthetics.
When fireplace is first lit, the flames will be blue. Flames will gradually turn yellowish-orange during first 15 minutes of operation. If
flames remain blue or become dark orange with evidence of sooting (black tips), the burner tube venturi may need adjustment.
WARNING: BURNER TUBE ADJUSTABLE VENTURI POSITIONING SHOULD ONLY BE PERFORMED BY A QUALIFIED
PROFESSIONAL SERVICE TECHNICIAN.
WARNING: TO AVOID PROPERTY DAMAGE OR PERSONAL INJURY, ALLOW FIREPLACE AMPLE TIME TO COOL
BEFORE MAKING ANY ADJUSTMENTS.
FACTORY SET BURNER TUBE VENTURI SETTINGS
(ADJUST AS NECESSARY FOR YOUR INSTALLATION)
NATURAL GAS
LP (PROPANE) GAS
1/16” (2 mm) OPEN
5/8” (16mm) OPEN
BURNER TUBE VENTURI ADJUSTMENT GUIDELINES
VENTURI POSITION
FLAME COLOR
VENTURI ADJUSTMENT
Closed too far
Dark orange flame with black tips
Open venturi setting slightly
Open too far
Blue flames
Close venturi setting slightly
NOTE: IF SOOT IS PRESENT, CHECK MEDIA POSITIONING BEFORE ADJUSTING BURNER VENTURI. MEDIA MUST NOT
BLOCK PILOT ASSEMBLY.
IMPORTANT: SLIGHT ADJUSTMENTS TO THE BURNER VENTURI OPENING CREATE DRAMATIC RESULTS. ADJUST AT
SLIGHT INCREMENTS UNTIL DESIRED LOOK IS ACHIEVED. ALWAYS BURN FIREPLACE FOR AT LEAST
15 MINUTES AND ALLOW TIME TO COOL BEFORE MAKING ANY FURTHER ADJUSTMENTS.
1. Remove screen front and glass frame assembly. Refer to page 14.
2. Remove glass media.
3. Remove burner assembly.
4. Loosen screw on burner venturi and adjust as necessary. Tighten screws.
5. Reinstall all components previously removed.
6. Light fireplace and wait 15 minutes before determining if any further adjustments are
needed.
TO ADJUST VENTURIS:
BURNER VENTURI
PAGE 31
Figure 31a