22
NOTE
11.6, Restrictor Assembly and Installation, on pages 21 and 22, has information on restrictor installation in conjunction with venting
installation. 18.3, Restrictors, on page 42, has information on restrictor recommendations depending on burner flame appearance,
and instructions on installation after venting is completed.
CAUTION
This gas appliance must not be connected to or joined with any other chimney flue serving another appliance.
11.7
Horizontal and Vertical 8” x 5” Combination Venting
MAXIMUM: 20ft. (6.1m) Horizontal / 20ft. (6.1m) Vertical
MAXIMUM: 20ft. (6.1m) Horizontal / 20ft. (6.1m) Vertical
Figure 11.7,
Natural Gas
Combination Venting
Using 8” x 5” Pipe
Figure 11.8,
LP Gas
Combination Venting
Using 8” x 5” Pipe
Slide restrictor into exhaust pipe on top of fireplace with
tabs pointing towards you prior to attaching venting.
When needed, remove
circle to create less
restriction
Bend tabs to approx. 80
°
angles to create tension to hold
itself in place when installed.
Restrictor
Figure 11.6, Restrictor Assembly and Installation