28
1. Run the duct pipe to the register location.
2. If an oval pipe is to be used in conjunction with the 6 in. (152 mm) round
duct pipe,
A. Shape the 6 in. (152 mm) round duct pipe to fit
outside
the oval duct
pipe. Secure with the screws provided.
B. Slide the oval duct pipe over the oval collar on the register mounting
bracket. Secure with the sheet metal screws provided.
OPTIONAL: Secure duct pipe with any additional screws provided.
3. If an oval duct pipe is not used,
A. Shape the 6 in. (152 mm) round duct pipe so it will fit
outside
the oval
collar on the register mounting bracket.
B. Slide the round duct pipe until it touches the register mounting bracket.
C. Position the locking strap around the 6 in. (152 mm) duct pipe, above
the crimped metal.
D. Pull the locking strap tight enough to firmly secure the duct pipe.
1. Install sheetrock or wall finish material as desired before attaching the register
cover and fan housing cover plate.
2. Position the cut-out portion of the fan housing cover plate over the fan chute to
allow air flow. Align the holes in the fan housing cover plate to the
corresponding holes in the register mounting plate and fan assembly. Secure
with (4) screws provided.
3. Slide the speed control through the mounting bracket. Secure with the mounting
nut.
4. Secure mounting bracket to the junction box with the (2) screws provided.
5. Center the register cover over the fan housing cover plate to install. Secure
register cover to stud wall with the provided mounting screws.
6. Attach a cover plate (not provided), then install the control knob for the speed
control.
7. Complete the fireplace installation by following the instructions included with the
fireplace.
1. After complete fireplace installation and subsequent initial burn period, turn the fireplace burner ON by following the lighting
instructions included with the fireplace.
2. Allow the fireplace to produce heat for approximately 15 minutes.
3. To operate the heat duct fan, turn the wall-mounted speed control
clockwise
until it stops. The fan should turn on and be
operating at its highest speed. Adjust the speed to desired air flow level by turning the speed control knob
counter-clockwise
until it ‘clicks’ off.
The duct register must be kept clear and unobstructed. Clean and vacuum as necessary to remove dust, lint, etc. from fan
which will inhibit air flow.
Detach the register cover and the fan housing cover plate at least once a year to remove dust, lint, etc. from the fan. More
frequent cleaning may be necessary.
The fireplace must be maintained and serviced as outlined in the unit installation and operating instructions.
12.5
Run and Secure Duct Pipe
12.6
Complete the Installation
12.7
Operating Instructions
12.8
Maintenance
Figure 12.6, Secured Duct Pipe
Figure 12.7,
Completed Installation