32
CAUTION
If burner and/or pilot have been burning, use appropriate protection to avoid burns or damage to personal property before removing any components.
WARNING
DO NOT OPERATE THIS FIREPLACE WITHOUT SEALING GASKET (LOCATED UNDER THE CONTROL BOARD) IN PLACE. IF GASKETING IS
DAMAGED, IT MUST BE REPLACED.
CAUTION
CHECK ALL CONNECTIONS FOR LEAKS WITH SOAPY WATER, WHETHER FIELD OR FACTORY MADE.
13.5
Control Board
13.5.1
Control Board Removal
Figure 13.6, Control Board Removal and Installation
4
5
Pilot
Burner orifice
3
2
1
1. Place control board in firebox, aligning holes in board to holes in
firebox bottom.
MAKE SURE SEALING GASKET IS IN PLACE ON FIREBOX
BOTTOM!
Secure with (8) screws previously removed.
2. Reinstall light bar onto control board, secure with (2) nuts
previously removed.
3. Reinstall burner, positioning burner venturi over burner orifice, align-
ing burner tube with mounting cradles on control board. Re-install
burner venturi housing.
4. Reinstall burner cover, aligning holes in cover to corresponding
holes in burner tube mounting cradles. Secure with screws (10).
5. Reinstall glass media, being careful not to block pilot.
6. Turn the manual valve counterclockwise to the ON postion.
7. Reconnect electrical power.
8. Reinstall glass frame assembly and safety barrier.
9. Verify proper glass media placement, operation of fireplace, and any
electrical components.
13.5.2
Control Board Installation
1. Disconnect electrical power.
2. Locate the manual valve installed by your qualified service
technician.
3. Turn the manual valve clockwise to the OFF position.
4. Remove glass frame assembly and safety barrier.
5. Remove glass media.
6. Remove burner cover (secured with [10] screws).
7. Remove burner venturi housing. Remove burner tube from
mounting cradles.
8. Remove (2) nuts securing light bar to control board, carefully move
light bar backwards far enough to clear board.
9. Remove (8) screws securing control board, lift board out of firebox
being careful not to damage sealing gasket lying underneath.