36
This system has the option of a continuous (standing) pilot feature. This allows
you to change from a spark-to-pilot system to a standing pilot system during cold
weather conditions. By having the pilot on continuously, the firebox will remain
warm and a draft is established in the vent, allowing the main burner to turn on
with less air-flow disruption.
With system in OFF position, press Mode Key to index to CPI mode icon.
Pressing the UP Arrow Key will activate the Continuous Pilot Ignition Mode (CPI).
Pressing the Down Arrow Key will return to IPI. A single beep will confirm the
reception of the command.
A snowflake icon will be visible during setup of either IPI or CPI modes.
In IPI mode, the snowflake is not visible on LCD screen.
In CPI mode, the snowflake will remain visible on LCD screen.
REMOTE CONTROL
: Remote control battery lifespan depends on various
factors
including battery quality, number of ignitions, changes to room thermostat set
point, etc. When the remote control batteries are low, a Battery Icon will appear on
the LCD display before all battery power is lost. When batteries are replaced this
icon will disappear.
BACKUP BATTERY PACK (used when electrical power is interrupted)
:
Backup batteries lifespan depends on various factors including battery quality,
number of ignitions, changes to room thermostat set point, etc. When backup
batteries are low, a double-beep will be emitted from the IFC control module when
it receives an ON/OFF command from the remote control. This is an alert for a low
battery condition of the backup batteries and after this double-beep warning, no
commands will be accepted until batteries are replaced. When batteries are
replaced, a beep will be emitted from IFC control module as soon as powered.
1. Put ON/OFF switch in OFF position.
2. Press red SW1 button on IFC control module until the IFC control module
emits three (3) beeps and an amber LED is illuminated, indicating the IFC
control module is ready to synchronize with remote control. Within five (5)
seconds press the red SW1 button on IFC control module again. The pilot will
automatically light.
3. Turn main burner on by pressing ON/OFF switch to ON position, turn off by
pressing ON/OFF switch to OFF position. Pilot will remain lit even if burner is
turned off.
When operating fireplace in this capacity, the only function available is burner
operation on HI.
This system will execute an automatic turn OFF command within (24) hours of a continued pilot flame ignition. This allows the
system to verify correct safety functions. After turn OFF sequence is completed, the IFC control module will re-execute the
latest command.
Figure 15.10, IFC Control Module
SW1 Button
LEDs
15.10
Low Battery Detection
15.11
Continuous Pilot / Intermittent Pilot (CPI/IPI)
15.12
Resetting System for Manual Operation
15.13
Automatic Safety Restart
Figure 15.8,
Low Battery Indicator
Figure 15.9, Pilot Indicator