3
This appliance has been tested by OMNI-Test Laboratories located in Portland, Oregon and complies with:
ANSI Z21.88-2014/CSA 2.33-2014, “Vented Gas Fireplace Heaters”
CGA 2.17-M91 (R2009), “Gas-Fired Appliances for Use at High Altitudes”
CSA P.4.1-2009, “Testing Method for Measuring Annual Fireplace Efficiency”
This installation must conform with local codes, or in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/
NFPA 54,
or the
Natural Gas and Propane Installation Code, CSA B149.1
This appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with
the
National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1
1.0
INTRODUCTION
1.1
Appliance Certification
Installation and repair should be done only by a qualified service person. The appliance should be inspected by a
qualified service person before use. Annual inspection by a qualified service person is required to maintain
warranty. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is
imperative that control compartments, burners, and circulation air passageways of the appliance be kept clean.
If this appliance is installed directly on carpeting, tile, or other combustible material other than wood flooring, the
appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid
burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young
children, and others may be susceptible to accidental contact burns. A physical barrier is recommended if there
are at-risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to
keep toddlers, young children, and other at-risk individuals out of the room and away from hot surfaces.
Clothing or other flammable material should not be placed on or near the appliance.
Adequate accessibility clearances for servicing and proper operation must be maintained.
This appliance must not share, or be connected, to a chimney flue serving any other appliance.
Keep area around the appliance clear of combustible materials, gasoline, and other flammable vapor and liquids.
The flow of combustion and ventilation air must not be obstructed.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
The glass front, or any part removed for servicing the appliance, must be replaced prior to operating the appliance.
Work should be done by a qualified service technician.
Clean glass only when cool and only with non-abrasive cleansers.
WARNING: DO NOT OPERATE APPLIANCE WITH THE GLASS/FRAME ASSEMBLY REMOVED, CRACKED, OR
BROKEN. REPLACEMENT OF THE GLASS SHOULD ONLY BE PERFORMED BY A LICENSED OR
QUALIFIED SERVICE PERSON.
The glass assembly, Part #SL36-057T, shall only be replaced as a complete unit, as supplied by Hussong Mfg. Co.,
Inc. DO NOT SUBSTITUTE MATERIALS.
Do not strike or slam glass assembly.
A safety barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and
shall be installed for the protection of children and other at-risk individuals.
Any safety screen, guard, or barrier removed for servicing the appliance must be replaced prior to operating the
appliance.
If the safety barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this
appliance.
For use only with the following safety barriers: Part Numbers SL36-MSF, SL36-RSF, SL36-BSF, or SL36-CXCF, as
supplied by Hussong Mfg. Co., Inc.
Under no circumstances should any solid fuel (wood, coal, paper, cardboard, etc.) be used in this appliance.
Keep burner and control compartment clean.
Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect
this appliance and to replace any part of the control system and any gas control which has been under water.
1.2
Safety Information