Kracht GmbH
Transport and storage | 5
88046020002
27 / 46
5 Transport and storage
5.1 General
a) After receipt, check the device for transport damages.
b) If transport damage is noticed, report this immediately to the manufacturer and the car-
rier. The device must then be replaced or repaired.
c) Dispose of packing material and used parts in accordance with the local stipulations.
5.2 Storage
The device's function is tested in the plant with mineral hydraulic oil. Then all connections are
closed. The remaining residual oil preserves the interior parts for up to 6 months.
Metallic exposed exterior parts are protected against corrosion by suitable conservation
measures, also up to 6 months.
In case of storage, a dry, dust-free and low-vibration environment is to be ensured. The
device is to be protected against influences from weather, moisture and strong fluctuations
of temperature. The recommended storage conditions are to be adhered to.
Below the permissible ambient temperature ϑ
U
elastomer seals lose their elasticity and mech-
anical loading capacity, since the glass transition temperature is fallen below. This procedure
is reversible. A force action on the device is to be avoided in case of storage below the per-
missible ambient temperature ϑ
U
.
Devices with EPDM seals are not mineral-oil resistant and are not tested for their function.
There is no preservation of the interior parts. If the device is not taken into operation imme-
diately, all corrosion-prone surfaces are to be protected by suitable conservation measures.
The same applies for devices which are not tested for other reasons
When storing for a long period of time (> 6 months), treat all surfaces at risk of corrosion
again with suitable preserving agents.
If high air humidity or aggressive atmospheres are expected, take additional corrosion-pre-
venting measures.
NOTICE
Storage in corrosion protection bags (VCI) maximum of 6 months.
ATTENTION
Corrosion/chemical impact
Improper storage can render the device useless.
a) Protect endangered surfaces by means of suitable conservation measures.
b) Comply with recommended storage conditions.
Summary of Contents for VC PULSE Series
Page 1: ...VC PULSE English 03 04 01 2021 D 0046020002 Operating Instructions Translation ...
Page 18: ...4 Technical data Kracht GmbH 18 46 88046020002 VC 0 2 VC 0 4 VC 1 ...
Page 19: ...Kracht GmbH Technical data 4 88046020002 19 46 VC 3 VC 5 VC 12 VC 16 ...
Page 20: ...4 Technical data Kracht GmbH 20 46 88046020002 4 4 2 Plain bearings VC 0 025 VC 0 1 ...
Page 21: ...Kracht GmbH Technical data 4 88046020002 21 46 VC 0 2 VC 0 4 VC 1 ...
Page 26: ...4 Technical data Kracht GmbH 26 46 88046020002 4 9 Dimensions ...