6 | Installation
Kracht GmbH
32 / 46
88046020002
6.2.3 Pipe connection
a) Clean all lines.
ð
Do not use cleaning wool.
ð
Pickle and flush welded pipes.
b) Remove the protective plugs.
c) Mount the lines.
ð
Comply with the manufacturer's information.
ð
Do not use any sealing materials such as hemp, Teflon tape or putty.
6.2.4 Rotary encoder
6.2.4.1 Plug alignment
The alignment of the connector can be set by the customer as required. The VC does not
need to be removed from the hydraulic system for this purpose.
NOTICE
No current is allowed to flow through the unit.
a) Loosen the nut by hand
b) Align plug
c) Tighten nut hand-tight
6.2.4.2 Replacement of the encoder
The encoder can be replaced at any time by another encoder purchased from the manufac-
turer. This is used, for example, to change the resolution or to detect an electronic defect.
The VC does not need to be removed from the hydraulic system for this purpose.
NOTICE
No current is allowed to flow through the unit.
a) Loosen the nut by hand
b) Completely remove the encoder assembly
c) Insert new encoder module
d) Tighten nut hand-tight
Summary of Contents for VC PULSE Series
Page 1: ...VC PULSE English 03 04 01 2021 D 0046020002 Operating Instructions Translation ...
Page 18: ...4 Technical data Kracht GmbH 18 46 88046020002 VC 0 2 VC 0 4 VC 1 ...
Page 19: ...Kracht GmbH Technical data 4 88046020002 19 46 VC 3 VC 5 VC 12 VC 16 ...
Page 20: ...4 Technical data Kracht GmbH 20 46 88046020002 4 4 2 Plain bearings VC 0 025 VC 0 1 ...
Page 21: ...Kracht GmbH Technical data 4 88046020002 21 46 VC 0 2 VC 0 4 VC 1 ...
Page 26: ...4 Technical data Kracht GmbH 26 46 88046020002 4 9 Dimensions ...