6 | Installation
Kracht GmbH
20 / 37
88025530002-11
WARNING
Failure of load-carrying parts due to overload!
Danger of injury from flying parts.
Danger of injury from spurting fluids.
a) Depressurise the device and all connection lines before doing any work.
b) Securely prevent the restoration of pressure while working on the device.
WARNING
Failure of pressure bearing parts due to overload
Risk of injury from flying parts.
Risk of injury due to fluid spurting out.
a) Use only connections and lines approved for the expected pressure range.
b) Securely prevent the permissible pressures from being exceeded, e.g. by using pressure
relief valves or bursting discs.
c) Pipelines must be designed in such a way that no tension e.g. caused by changes in
length due to fluctuations in temperature can be transferred to the product.
CAUTION
Hot surfaces
Burn injury to skin if touched.
a) Take measures against accidental touching of hot surfaces (> 60 °C).
6.2 Mechanical installation
6.2.1 Preparation
a) Check the device for transport damage and dirt.
b) Remove existing preservatives.
ð
Use only those cleaning agents that are compatible with the materials used in the
device.
ð
Do not use cleaning wool.
c) Compare the environmental and ambient conditions at the place of installation to the
permissible conditions.
ð
Expose the device only to small vibrations, see IEC 60034-14.
ð
Secure sufficient access for maintenance and repair.
ð
Comply with the manufacturer's information.
ð
Do not use any sealing materials such as hemp, Teflon tape or putty.