27
КОМБИНИРОВАННАЯ ГАЗОЭЛЕКТРИЧЕСКАЯ ПЛИТА
СOMBINED ELECTRIC GAS STOVE
ИНСТРУКЦИЯ ПО ЭКСПЛУАТАЦИИ • USER GUIDE
5. Set the handle back and quickly turn it from the maximum position to the minimum, making
sure that the flame does not go out.
6. For burners with a safety valve, make sure that this setting is sufficient to maintain the
heating of the thermocouple. Otherwise, increase the minimum flame level.
MINIMUM ADJUSTMENT FOR LIQUEFIED GAS
To set the minimum for liquefied gas, completely tighten the screw installed inside or on
the side of the valve stem clockwise.
IMPOrTaNT! The burners do not require primary adjustment.
TABLE OF INJECTORS AND GAS FLOW
GAS TYPE
Small burner
Medium burner
Big burner
injector
gas
consumption
injector
gas
consumption
injector
gas
consumption
SABAF
SABAF
SABAF
LPG
G30-30 mbar
0,55
0,50
73 g/h
0,70
0,65
131 g/h
0,85
0,85
204 g/h
G31-37 mbar
0,55
—
73 g/h
0,70
—
131 g/h
0,85
—
204 g/h
G30-37 mbar
0,50
—
70 g/h
0,65
—
127 g/h
0,80
—
190 g/h
G30-50 mbar
0,50
0,43
76 g/h
0,65
0,58
145 g/h
0,80
0,75
207 g/h
NG
G20-20 mbar
0,75
0,72
0,095 m
3
/h
1,00
0,97
0,167 m
3
/h 1,20
1,15
0,271 m
3
/h
G20-25 mbar
0,70
0,68
0,095 m
3
/h
0,95
0,91
0,171 m
3
/h 1,15
1,10
0,276 m
3
/h
G25-25 mbar
0,75
0,74
0,095 m
3
/h
1,00
0,98
0,167 m
3
/h 1,20
1,25
0,271 m
3
/h
ELECTRICAL CONNECTION
The appliance must be connected to the main electrical network in accordance with
applicable laws and regulations.
• Make sure that the power from the main network is sufficient for the power supply system
is grounded in accordance with current regulations, and the power cable does not come
into contact with the heated elements.
• Do not use adapters, extension cords, or "tees" to connect the appliance.
• If you need to replace the power cord, make sure that it meets current standards and
meets the product specifications.
GROUNDING
• This appliance requires grounding to protect it from short circuits and electrical dissipation. It
is equipped with a grounded plug installed on the power cord. Therefore, the appliance must
be connected to an appropriate electrical outlet.
• The installation, connection and grounding of the electrical system must correspond to the
provisions of European standards, as well as applicable local regulations.
• The ground cable must not be interrupted by a switch. If your apartment does not have a
ground connection, contact a qualified electrician to install it.