15 Accessories
15.1 Installation
Further faults
Cause and elimination
Overflow of the total
value
After an overflow of the total value the electronic unit displays the following:
o
For 3 decimal places:
±1 999 999,999
o
For 1 decimal place:
±199 999 999,9
o
Specify another unit for Total, e.g. m
3
instead of l. After the modification, the Total value is still
available after the overflow.
o
Reduce the number of decimal places.
15 Accessories
15.1 Installation
15.1.1
Fixing kits
The electronic unit can be installed by various methods. In addition to the mounting frame that forms
part of the scope of delivery, diverse fixing kits for mounting the electronic unit are available as ac-
cessories.
15.1.2
Universal mount fixing kit
Fixing kit
Application
Article No.
Suitable for
Wall mounting
UZA 20
BEM 300
BEM 500
117,2
96
9
6
7
0
70
1
1
7
100
1
0
0
8,5
9
Fig. 3: Mounting dimensions of universal mount
UZA 20
Mounting: M8
26
OIE 15en-GB Edition 2020-03
Operating instructions