4. Connect the two LC optical fibers between
617T
and
617R
.
Connect (A) to (A) and (B) to (B). Make sure that the duplex connectors are connected
properly.
The STATUS LED flashes.
Do not look directly into the LC connectors on the
617T
(the transmitter side)
when it’s powered.
This product operates under LASER Class I, classified by CDRH/FDA for eye
safety.
We recommend that you avoid using intermediate cables or adapters. Using
them may affect the transmission quality.
5. Connect
617T
to the HDMI connector on the source side and
617R
on the acceptor side.
Make sure that the
617T
is always connected to the source side and the
617R
is connected to the acceptor side.
Once the system is connected the Status LEDs on both
617T
and
617R
flash.
Troubleshooting
If the display appears black:
•
Check that the power source adapters are properly connected on both sides.
•
Check that both HDMI connector heads are fully plugged into the devices.
•
Check that the source and display devices are both switched on.
•
Reset the system by disconnecting and then reconnecting the
617T
or
617R
, or by
disconnecting and then reconnecting the power adapters.
•
Reboot the system.