50
Kramer Protocol 3000
Command -
RESET
Command Type - System-mandatory
Command Name
Permission
Transparency
Set:
RESET
Administrator
Public
Get:
-
-
-
Description
Syntax
Set:
Reset device
#
RESET
␍
Get:
-
-
Response
~nn@
RESET
␠
OK
␍␊
Parameters
Response triggers
Notes
To avoid locking the port due to a USB bug in Windows, disconnect USB connections immediately after
running this command. If the port was locked, disconnect and reconnect the cable to reopen the port.
Command -
SECUR
Command Type - Authentication
Command Name
Permission
Transparency
Set:
SECUR
Administrator
Public
Get:
SECUR?
Not Secure
Public
Description
Syntax
Set:
Set security
#
SECUR
␠
security_mode
␍
Get:
Get current security state
#
SECUR?
␍
Response
Set: ~nn
@SECUR
␠
security_mode
␠
OK
␍␊
Get: ~nn
@SECUR
␠
security_mode
␍␊
Parameters
security_mode
– 1/ON - enables security, 0/OFF - disables security
Response triggers
Notes
The permission system works only if security is enabled with the “SECUR” command