Enabling Auto Switching
If the auto-switching was disabled (for example, by following the procedure described above),
you can enable it once again.
To enable the auto-switching:
1. On the
KIT-400T
rear panel, set both video DIP-switches 1 and 2 to Off (up),
2. Power-cycle the device.
3. In the Navigation pane click
Device Settings
and perform Factory reset (see
4. In the Navigation pane, click
Automation
. The Automation page appears (see
5. Click
Triggers
. The Triggers area opens.
6. Select
Last Off
trigger.
7. In the Trigger area, next to Script to run, click
Enabled
.
8. Repeat the last 2 steps for the next three triggers:
▪
Port Connectivity 1.
▪
Port Connectivity 2.
▪
Port Connectivity 3.
9. Click
Save All
.
10. Make sure all 5 default triggers are enabled.
11. On the
KIT-400T
rear panel, set both video DIP-switches 1 and 2 to OFF (up),
12. Power-cycle the device.
Auto-switching is enabled.
Operating via Room Automation Panel
You can control
KIT-400
via any of Kramer’s touch panels (for example,
KT-1010
) which
include the
Kramer Aware
app.
KIT-400
enables performing the following actions:
•
Viewing and Carrying out actions via the control panel in the Automation Page.
•
Editing the device control panel.